ON THE UNDERSTANDING OF CLINICAL INSTABILITY

被引:59
作者
PANJABI, MM
LYDON, C
VASAVADA, A
GROB, D
CRISCO, JJ
DVORAK, J
机构
[1] Biomechanics Laboratory, Department of Orthopaedics and Rehabilitation, Yale University School of Medicine, New Haven, CT
[2] Spine Unit, Wilhelm Schulthess Hospital, Zürich
关键词
CERVICAL SPINE; EXTERNAL SPINAL FIXATOR; NEUTRAL ZONE; SPINAL BIOMECHANICS; SPINAL INSTABILITY;
D O I
10.1097/00007632-199412000-00008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Three-dimensional flexibility changes due to the application of an external fixator at C4-C5 were studied in cervical spine specimens. Objectives. To evaluate the biomechanical effects of applying a cervical external fixator to a patient using an in vitro model. Summary of Background Data. There is controversy regarding the relationship between the changes in spinal motion and clinical instability. Methods. Using fresh cadaveric C4-C7 specimens, multidirectional flexibility was measured at all vertebral levels, before and after the fixator application at C4-C5, C5-C6, and C4-C6. Results. The average ranges of motion for flexion, extension, lateral bending, and axial rotation were 8.3-degrees, 7.2-degrees, 5.3-degrees, and 5.6-degrees, which decreased by 40%, 27%, 32%, and 58%, respectively, because of the fixator application. The corresponding neutral zones were 3.4-degrees, 3.4-degrees, 3.0-degrees, and 2.0-degrees, which decreased by 76%, 76%, 54%, and 69%, respectively. The decreases with the fixation at C4-C5 were similar to those for fixation at C5-C6. Conclusions. This in vitro study documented that the application of an external fixator to the cervical spine decreases the intervertebral motion in general, and decreases flexion, extension and torsional neutral zones in particular. The findings help explain the clinical instability of the spine and support the hypothesis that the neutral zone is more closely associated with the clinical instability than is the range of motion.
引用
收藏
页码:2642 / 2650
页数:9
相关论文
共 22 条
[1]  
Dvorak J., Personal Communication, (1993)
[2]  
Dvorak J., Antinnes Ja Panjabi M.M., Loustalot D., Bonomo M., Age and gender related normal motion of the cervical spine, Spine, 17, pp. 393-398, (1992)
[3]  
Dvorak J., Panjabi M.M., Grob D., Novotny J.E., Antinnes J.A., A clinical validation of functional flexion/extension radiographs of the cervical spine, Spine, 18, pp. 120-127, (1993)
[4]  
Dvorak J., Panjabi M.M., Novotny J.E., Chang D., Grob D., Clinical validation of functional flexion/extension x-rays of the lumbar spine, Spine, 16, pp. 943-950, (1991)
[5]  
Friberg O., Lumbar instability: A dynamic approach by traction- compression radiography, Spine, 12, pp. 119-129, (1987)
[6]  
Grob D., Dvorak J., Panjabi M.M., Antinnes J.A., Fixateur externe an der Halswirbelsäule, ein neues diagnostisches Mittel, Der Unfallchirurg, 96, pp. 416-421, (1993)
[7]  
Grob D., Jeanneret B., Aebi M., Markwalder T., Atlantoaxial fusion with transarticular screw fixation, J Bone Joint Surg [Br], 73, pp. 972-976, (1991)
[8]  
Grob D., Magerl F., Operative Stabilisierung bei Frakturen von C1 und C2, Orthopäde, 16, pp. 46-54, (1987)
[9]  
Knutsson F., The instability associated with disk degeneration in the lumbar spine, Acta Radiol, 25, pp. 593-608, (1944)
[10]  
Lehmann T., Brand R., Instability of the Lower Lumbar Spine, (1982)