NONDISPLACED FRACTURES - SPATIAL-RESOLUTION REQUIREMENTS FOR DETECTION WITH DIGITAL SKELETAL IMAGING

被引:79
作者
MURPHEY, MD
BRAMBLE, JM
COOK, LT
MARTIN, NL
DWYER, SJ
机构
[1] Department of Diagnostic Radiology, University of Kansas Medical Center, Kansas City, KS 66103
关键词
Diagnostic radiology; observer performance; Fractures; 40.41; Radiography; digital; 40.1215; Receiver operating characteristic curve (ROC); Video systems;
D O I
10.1148/radiology.174.3.2305071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fifty-six radiographs of nondisplaced or minimally displaced fractures of the extremities and an equal number of studies with normal findings were selected and digitized to produce spatial resolution varying from 5.75 to 0.72 line pairs per millimeter (lp/mm), corresponding to pixel sizes ranging from 0.08 to 0.64 mm. The conventional and digitized images were evaluated by 10 radiologists, who gave their decision confidence on a graded scale. Receiver operating characteristic analyses were performed from these data to compare the digital images with the conventional radiographs. There was a progressive improvement in observer performance as the pixel size decreased. A pixel size greater than 0.16 mm (2.88 lp/mm) resulted in a significant loss of diagnostic accuracy in comparison with conventional radiographs. Specific fractures in which a larger pixel size adversely affected the evaluation included torus injuries, corner fractures in child abuse, minimal avulsion injuries, and fractures that demonstrated only trabecular disruption.
引用
收藏
页码:865 / 870
页数:6
相关论文
共 30 条
  • [1] ADAPTIVE HISTOGRAM EQUALIZATION IN DIGITAL RADIOGRAPHY OF DESTRUCTIVE SKELETAL LESIONS
    BRAUNSTEIN, EM
    CAPEK, P
    BUCKWALTER, K
    BLAND, P
    MEYER, CR
    [J]. RADIOLOGY, 1988, 166 (03) : 883 - 885
  • [2] BRUNK HD, 1965, INTRO MATH STATISTIC, P250
  • [3] CAPP MP, 1985, RADIOL CLIN N AM, V23, P349
  • [4] DIGITAL AND CONVENTIONAL CHEST IMAGING - A MODIFIED ROC STUDY OF OBSERVER PERFORMANCE USING SIMULATED NODULES
    CHAKRABORTY, DP
    BREATNACH, ES
    YESTER, MV
    SOTO, B
    BARNES, GT
    FRASER, RG
    [J]. RADIOLOGY, 1986, 158 (01) : 35 - 39
  • [5] TELERADIOLOGY - RESULTS OF A FIELD TRIAL
    CURTIS, DJ
    GAYLER, BW
    GITLIN, JN
    HARRINGTON, MB
    [J]. RADIOLOGY, 1983, 149 (02) : 415 - 418
  • [6] THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS
    FOLEY, WD
    WILSON, CR
    KEYES, GS
    DIBIANCA, FA
    SCANLON, GT
    SCHLEUTER, D
    LAWSON, TL
    [J]. RADIOLOGY, 1981, 141 (01) : 25 - 31
  • [7] FRASER RG, 1983, RADIOLOGY, V148, P1
  • [8] TELERADIOLOGY - AN EVALUATION OF A MICROCOMPUTER-BASED SYSTEM
    GAYLER, BW
    GITLIN, JN
    RAPPAPORT, W
    SKINNER, FL
    CERVA, J
    [J]. RADIOLOGY, 1981, 140 (02) : 355 - 361
  • [9] GENANT H K, 1977, Radiology, V123, P47
  • [10] GITLIN JN, 1986, RADIOL CLIN N AM, V24, P55