COMPARING THE CELL-POPULATION ON DIFFERENT INTRAOCULAR-LENS MATERIALS IN ONE EYE

被引:9
作者
OKADA, K
FUNAHASHI, M
ISEKI, K
ISHII, Y
机构
[1] Second Department of Ophthalmology, Toho University School of Medicine, Tokyo
[2] Funahashi Eye Clinic, Aichi
[3] Menicon Inc., Nagoya
关键词
CELL ADHESION; GIANT CELL; HALF COATING; INTRAOCULAR LENS; POLY(METHYL METHACRYLATE); SILICONE; SPECULAR MICROSCOPY;
D O I
10.1016/S0886-3350(13)80321-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We developed a method to evaluate cell adherence to different intraocular lens (IOL) materials in one eye in which we coated one half of the anterior surface of a poly(methyl methacrylate) (PMMA) IOL with poly(dimethyl siloxane), a silicone material. The lenses were implanted in the anterior chamber of rabbit eyes without lens extraction. Postoperative cellular reaction on the IOL surfaces was studied by specular microscopy. The IOLs were fixed in situ, removed from the eyes, and stained with hematoxylin-eosin so we could evaluate the cell population on the silicone and PMMA surface. Fewer cells were scattered on the silicone surface than on the PMMA surface. This method excludes surgical effects and allows a comparison of various IOL materials in the same eye.
引用
收藏
页码:431 / 434
页数:4
相关论文
共 14 条
[1]  
Buchen SY, Richards SC, Solomon KD, Et al., Evaluation of the biocompatibility and fixation of a new silicone intraocular lens in the feline model, J Cataract Refract Surg, 15, pp. 545-553, (1989)
[2]  
Ygge J, Wenzel M, Philipson B, Fagerholm P, Cellular reactions on heparin surface-modified versus regular PMMA lenses during the first postoperative month: A double-masked and randomized study using specular microscopy, Ophthalmology, 97, pp. 1216-1224, (1990)
[3]  
Okada K, Tobari I, Postoperative cellular reaction on surface modified intraocular lenses in living human eyes, J Cataract Refract Surg, 17, pp. 319-323, (1991)
[4]  
Menapace R, Juchem M, Skorpik C, Kulnig W, Clinicopathologic findings after in-the-bag implantation of openloop polymethylmethacrylate and silicone lenses in the rabbit eye, J Cataract Refract Surg, 13, pp. 630-634, (1987)
[5]  
Cook CS, Peiffer RL, Mazzocco TR, Clinical and pathologic evaluation of a flexible silicone posterior chamber lens design in a rabbit model, J Cataract Refract Surg, 12, pp. 130-134, (1986)
[6]  
Kulnig W, Menapace R, Skorpik C, Juchem M, Tissue reaction after silicone and poly(methyl methacrylate) intraocular lens implantation: A light and electron micros copy study in a rabbit model, J Cataract Refract Surg, 15, pp. 510-518, (1989)
[7]  
Okada K, Takahashi K, Sagawa H, Abe K, Evaluation of the images of specular microscopy of the cells on implanted intraocular lenses in vivo, Cells and Materials, 1, pp. 119-128, (1991)
[8]  
Okada K, Sagawa H, Newton rings on the surface of implanted intraocular lenses, Ophthalmic Surg, 20, pp. 33-37, (1989)
[9]  
Wolter JR, Lens implant cytology, Ophthalmic Surg, 13, pp. 939-942, (1982)
[10]  
Wolter JR, Cytopathology of intraocular lens implantation, Ophthalmology, 92, pp. 135-142, (1985)