ASSESSING DIFFUSE LIVER-DISEASE WITH THE HEPATIC-UPTAKE RATE OF TC-99(M)-COLLOIDS

被引:4
作者
RUTLAND, MD
QUE, L
机构
[1] Department of Nuclear Medicine, Auckland Hospital, Auckland, Park Road
关键词
D O I
10.1097/00006231-199501000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The hepatic uptake rate of sulphur or tin colloid tvas measured in the fasting state in patients who were later identified as belonging to one of three groups: normal, parenchymal liver disease or cirrhosis. Subsequent analysis showed a progressive decline in the hepatic uptake rate of tracer as the severity of hepatocellular damage increased. In particular, there was a positive correlation between the impairment of tracer uptake, and Childs' class A, B or C in the cirrhotic patients. In addition, a very low hepatic uptake rate of tracer was almost as good (80% accuracy) as Childs' class C (83% accuracy) in identifying patients likely to die of hepatocellular problems within a year. When compared with needle biopsies or histology, the uptake rate usually proved equally accurate in indicating the severity of diffuse hepatocellular disease, and on occasions it was a better indicator of long-term outcome.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 11 条
[1]  
Mc Dermott W.V., Greenberger N.J., Isselbacher K.S., Weber A.L., Major hepatic resection: Diagnostic techniques and metabolic problems, Surgery, 54, (1963)
[2]  
Maharaj B., Patel A., Bhoora I.G., Maharaj J., Ultrasonography and scintigraphy in liver disease, In Developing Countries. Lancet, 7, (1989)
[3]  
Rykins E.B., Fajmon W., Sarfer R., Et al., Radionuclide angiography of the liver and spleen - noninvasive method for assessing the ratio of portal venous to total hepatic blood flow and porto-systemic shunt patency, Am J Surg, 142, pp. 574-579, (1981)
[4]  
Wraight E.P., Barber R.W., Ritson A., Relative hepatic arterial and portal flow in liver scintigraphy, Nucl Med Commun, 3, pp. 273-279, (1982)
[5]  
Rutland M.D., An analysis of the uptake of 99m-Tc-sulphur colloid by liver and spleen, Nucl Med Commun, 5, pp. 593-602, (1984)
[6]  
Graham L.G., Neill R., In vivo quantitation of radioactivity using the gamma camera, Radiology, 112, pp. 441-442, (1974)
[7]  
Fleming J.S., A technique for the absolute measurement of activity using a gamma camera and computer, Phys Med Biol, 24, pp. 176-180, (1979)
[8]  
Turner J., Rutland M.D., Gamma ray attenuation and quantitative gamma camera studies, Aust NZ Med, 18, (1988)
[9]  
Patton D.D., Garcia E.N., Webber M.M., Simplified prepara-tion of Tc-99m-sulphur colloid for liver scanning, Am J Roentgenol, 97, pp. 880-885, (1966)
[10]  
Pugh R., Murray-Lyon I.M., Dawson J.L., Et al., Transection of the oesophagus for bleeding oesophageal varices, Br J Surg, 60, pp. 646-649, (1973)