A PASSIVE SAMPLER FOR ATMOSPHERIC OZONE

被引:48
作者
GROSJEAN, D
HISHAM, MWM
机构
[1] DGA Inc., Ventura, CA
[2] Daniel Grosjean and Associates Inc., DGA, Ventura, CA, 93003, 4526 Telephone Road
[3] Occidental Chemical Corporation, Grand Island, NY
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 1992年 / 42卷 / 02期
关键词
D O I
10.1080/10473289.1992.10466980
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple, cost-effective passive sampler has been developed for the determination of atmospheric ozone. This passive sampler is based on a colorant which fades upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Direct, on-site measurements are possible, and no chemical analyses are needed. Sampler design and validation studies have been carried out and included quantitative determination of color change vs exposure time (1-8 days), color change vs. ozone concentration (30-350 ppb), and response to changes in sampler configuration that modify the passive sampling rate. With indigo carmine as the colorant, the detection limits are 30 ppb. day and 120 ppb. day using a plastic grid and a Teflon filter, respectively, as diffusion barriers. Interferences from nitrogen dioxide, formaldehyde and peroxyacetyl nitrate are 15, 4 and 16 percent, respectively, thus resulting in a negligible bias when measuring ozone in ambient air.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 22 条