DOES ANYBODY REALLY KNOW WHAT TIME IT IS - DOES ANYBODY REALLY CARE

被引:54
作者
CORDELL, WH
OLINGER, ML
KOZAK, PA
NYHUIS, AW
机构
[1] Emergency Medicine and Trauma Center Methodist Hospital of Indiana, Indianapolis
[2] the Department of Medical Research, Methodist Hospital of Indiana, Indianapolis
关键词
D O I
10.1016/S0196-0644(94)70099-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To evaluate the difference among time sources in an emergency medical system. Design: Prospective; comparison to a criterion standard. Setting: Five emergency departments and three emergency medical services systems in Indianapolis, Indiana. Interventions: Coordinated Universal Time (UTC), generated by the atomic clock in Boulder, Colorado, and broadcast by the US Commerce Department's National Institute of Standards and Technology, was used as the time standard. The investigators, on a single day, made unannounced visits to the five EDs and the ambulances and fire stations in the three emergency medical services systems. The times displayed on all time sources at each location were recorded. The accuracy to the second of each time source compared to UTC was calculated. Results: Three time sources were excluded (two defibrillator clocks and one ED wall clock that varied more than three hours from UTC). Of the 152 time sources, 72 had analog displays, 74 digital, three both, and three other. The average absolute difference from UTC was 1 minute 45 seconds (SEM, 9 seconds) with a range of 12 minutes 34 seconds slow to 7 minutes 7 seconds fast. Thus, two timepieces could have varied by as much as 19 minutes 41 seconds. Compared to UTC, 47 timepieces (31%) were slow, 100 (66%) were fast, and five (3%) were accurate to the second. Fifty-five percent of the time sources varied one minute or more from UTC. Conclusion: Time sources in this health care system varied considerably. Time recording in medicine could be made more precise by synchronizing medical clocks to UTC, using computers to automatically ''time stamp'' data entries and using only digital time sources with second displays.
引用
收藏
页码:1032 / 1036
页数:5
相关论文
共 10 条
  • [1] Lamm, Does Anybody Really Know What Time It is?, Aurelius Music, (1970)
  • [2] Mosesso, The most neglected tool in EMS: The clock, Ann Emerg Med, 22, pp. 1311-1312, (1993)
  • [3] Becker, Ostrander, Barrett, Et al., Outcome of CPR in a large metropolitan area-Where are the survivors?, Ann Emerg Med, 20, pp. 355-361, (1991)
  • [4] Spaite, Valenzuela, Meislin, Et al., Prospective validation of a new model for evaluating emergency medical services systems by in-field observation of specific time intervals in prehospital care, Ann Emerg Med, 22, pp. 638-645, (1993)
  • [5] Cummins, Chamberlain, Abramson, Et al., Recommended guidelines for uniform reporting of data from out-of-hospital cardiac arrest The Utstein style, Annals of Emergency Medicine, 20, pp. 861-874, (1991)
  • [6] Valenzuela, Spaite, Meislin, Et al., Case and survival definitions in out-of-hospital cardiac arrest: Effect on survival rate calculation, JAMA, 267, pp. 272-274, (1992)
  • [7] Bock, Field verification methodology using bar coding to record data, Ann Emerg Med, 22, pp. 75-79, (1993)
  • [8] Stevens, Los Angeles county taps atomic clock to improve the timing of its stoplights, The Wall Street Journal November, 11, (1988)
  • [9] US Department of Commerce/National Bureau of Standards, A Walk Through Time, (1978)
  • [10] Coursey, Board and software combination fixes clock drift on networked, stand-alone PCs, PC Week June, 24, (1991)