DIFFERENCES BETWEEN THE TENSILE AND COMPRESSIVE STRENGTHS OF BOVINE TIBIAL TRABECULAR BONE DEPEND ON MODULUS

被引:257
作者
KEAVENY, TM
WACHTEL, EF
FORD, CM
HAYES, WC
机构
[1] BETH ISRAEL HOSP, CHARLES A DANA RES INST, DEPT ORTHOPAED SURG, ORTHOPAED BIOMECH LAB, BOSTON, MA 02215 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA USA
关键词
D O I
10.1016/0021-9290(94)90054-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The conflicting conclusions regarding the relationship between the tensile and compressive strengths of trabecular bone remain unexplained. To help resolve this issue, we compared measurements of the tensile (n = 22) and compressive (n = 22) yield strengths, and yield strains, of trabecular bone specimens taken from 38 bovine proximal tibiae. We also studied how these failure properties depended on modulus and apparent density. To enhance accuracy, trabecular orientation was controlled, and each specimen had a reduced section where strains were measured with a miniature extensometer. We found that the mean yield strength was 30% lower for tensile loading. However, the difference between individual values of the tensile and compressive strengths increased linearly with increasing modulus and density, being negligible for low moduli, but substantial for high moduli. By contrast, both the tensile and compressive yield strains were independent of modulus and density, with the yield strain being 30% lower for tensile loading. Thus, the difference between the tensile and compressive strengths of bovine tibial trabecular bone depends on the modulus, but the difference between yield strains does not. This phenomenon may explain in part that conflicting conclusions reached previously on the tensile and compressive strengths of trabecular bone since the mean modulus has varied among different studies. Realizing that our data pertain only directly to bovine tibial trabecular bone for longitudinal loading, our results nevertheless suggest that failure parameters based on strains may provide more powerful and general comparisons of the failure properties for trabecular bone than measures based on stresses.
引用
收藏
页码:1137 / 1146
页数:10
相关论文
共 36 条
  • [1] BENSUSAN JS, 1983, 29TH T ORTH RES SOC, P132
  • [2] COMPRESSIVE CREEP-BEHAVIOR OF BOVINE TRABECULAR BONE
    BOWMAN, SM
    KEAVENY, TM
    GIBSON, LJ
    HAYES, WC
    MCMAHON, TA
    [J]. JOURNAL OF BIOMECHANICS, 1994, 27 (03) : 301 - &
  • [3] MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR
    BROWN, TD
    FERGUSON, AB
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03): : 429 - 437
  • [4] CONTRIBUTION OF COLLAGEN AND MINERAL TO ELASTIC-PLASTIC PROPERTIES OF BONE
    BURSTEIN, AH
    ZIKA, JM
    HEIPLE, KG
    KLEIN, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (07) : 956 - 961
  • [5] COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE
    CARTER, DR
    HAYES, WC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) : 954 - 962
  • [6] TENSILE FRACTURE OF CANCELLOUS BONE
    CARTER, DR
    SCHWAB, GH
    SPENGLER, DM
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (05): : 733 - 741
  • [7] ANISOTROPIC YIELD BEHAVIOR OF BONE UNDER COMBINED AXIAL FORCE AND TORQUE
    CEZAYIRLIOGLU, H
    BAHNIUK, E
    DAVY, DT
    HEIPLE, KG
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (01) : 61 - 69
  • [8] EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY
    CIARELLI, MJ
    GOLDSTEIN, SA
    KUHN, JL
    CODY, DD
    BROWN, MB
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) : 674 - 682
  • [9] SOME VISCO-PLASTIC CHARACTERISTICS OF BOVINE AND HUMAN CORTICAL BONE
    FONDRK, M
    BAHNIUK, E
    DAVY, DT
    MICHAELS, C
    [J]. JOURNAL OF BIOMECHANICS, 1988, 21 (08) : 623 - 630
  • [10] PHYSICAL PROPERTIES OF TRABECULAR BONE
    GALANTE, J
    ROSTOKER, W
    RAY, RD
    [J]. CALCIFIED TISSUE RESEARCH, 1970, 5 (03): : 236 - &