EVALUATION OF A LINE IMMUNOASSAY FOR SIMULTANEOUS CONFIRMATION OF ANTIBODIES TO HIV-1 AND HIV-2

被引:21
作者
FRANSEN, K
POLLET, DE
PEETERS, M
VANKERCKHOVEN, I
BEELAERT, G
VERCAUTEREN, G
PIOT, P
VANDERGROEN, G
机构
[1] INST TROP MED PRINCE LEOPOLD,DEPT MICROBIOL,NATL STR 155,B-2000 ANTWERP,BELGIUM
[2] INNOGENET NV,B-2000 ANTWERP,BELGIUM
关键词
D O I
10.1007/BF02005448
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
An anti-HIV-1/HIV-2 line immunoassay (LIA), using peptides and recombinant antigens was evaluated against commercially available Western blot tests for HIV-1 and HIV-2 antibodies. Two thousand one hundred and ten sera of European, African, and South American origin were used in the evaluation. The panel included 1066 sera with antibodies to HIV-1, 192 sera with antibodies to HIV-2, and 64 sera with antibodies to both. Using Western blot results interpreted according to the WHO criteria as a reference standard, the overall specificity obtained by this LIA was 100 % and the sensitivity was 99.77 % (97.51-100 % for 95 % confidence limits) when sera dually reactive in Western blot were included. Of the three sera negative in the LIA but positive in HIV-1 WB, two could be retested in a radioimmunoprecipitation assay and were negative. When dually reactive sera in the Western blot (WHO) were included, the LIA yielded 9.9 % indeterminate results as compared with 15.5 % for both assays (chi(2) = 29.30; p < 0.001). Although only one HIV-2 specific peptide antigen (gp36) was used, the LIA yielded a specificity of 100 % and a sensitivity of 100 % as compared with the HIV-2 Western blot assay. When indeterminate results were included, the overall agreement between the LIA and the HIV-1 and HIV-2 Western blot (WHO criteria) was 89.9 % and 90.1 % respectively. These results indicate that the LIA provides reliable simultaneous detection of antibodies to HIV-1 and HIV-2, and at a cost which is substantially lower than the cost of Western blot tests.
引用
收藏
页码:939 / 946
页数:8
相关论文
共 25 条
  • [1] MULTICENTER EVALUATION OF A NEW RECOMBINANT ENZYME-IMMUNOASSAY FOR THE COMBINED DETECTION OF ANTIBODY TO HIV-1 AND HIV-2
    AYRES, L
    AVILLEZ, F
    GARCIABENITO, A
    DEINHARDT, F
    GURTLER, L
    DENIS, F
    LEONARD, G
    RANGER, S
    GROB, P
    JOLLERJEMELKA, H
    HESS, G
    SEIDL, S
    FLACKE, H
    SIMON, F
    BRUNVEZINET, F
    SONDAG, D
    ANDRE, A
    HAMPL, H
    SCHOEN, R
    STRAMER, S
    TROONEN, H
    [J]. AIDS, 1990, 4 (02) : 131 - 138
  • [2] BENESON A, 1990, JAMA-J AM MED ASSOC, V262, P3435
  • [3] SPECIFICITIES AND SENSITIVITIES OF 3 SYSTEMS FOR DETERMINATION OF ANTIBODIES TO HUMAN IMMUNODEFICIENCY VIRUS BY ELECTROPHORETIC IMMUNOBLOTTING
    BLOMBERG, J
    KLASSE, PJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (01) : 106 - 110
  • [4] INTERPRETING HIV ELISA REACTIVITY - ALTERNATIVES TO WESTERN BLOT
    BRITZ, JA
    ROLON, N
    HILL, T
    PAGE, E
    GELTOSKY, J
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1988, 2 (03) : 174 - 181
  • [5] BRUCKER G, 1987, LANCET, V1, P223
  • [6] COMPARISON OF 10 ENZYME IMMUNOASSAYS FOR DETECTION OF ANTIBODY TO HUMAN IMMUNODEFICIENCY VIRUS TYPE-2 IN WEST-AFRICAN SERA
    DENIS, F
    LEONARD, G
    SANGARE, A
    GERSHYDAMET, G
    REY, JL
    SORO, B
    SCHMIDT, D
    MOUNIER, M
    VERDIER, M
    BAILLOU, A
    BARIN, F
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (05) : 1000 - 1004
  • [7] HIV ANTIBODY SCREENING AND CONFIRMATORY TESTING OF ITALIAN BLOOD-DONORS - ONE-YEAR EXPERIENCE OF A REFERENCE CENTER
    FERRONI, P
    TAGGER, A
    PASQUALI, M
    PROFETA, ML
    [J]. VOX SANGUINIS, 1988, 55 (03) : 143 - 147
  • [8] GENESCA J, 1989, LANCET, V2, P1023
  • [9] LANTIN JP, 1989, CLIN EXP IMMUNOL, V76, P332
  • [10] LYONS SF, 1988, AIDS, V2, P406, DOI 10.1097/00002030-198810000-00020