IMPROVED SENSITIVITY AND SPECIFICITY OF A SINGLE MEASUREMENT OF SERUM PROGESTERONE OVER SERIAL QUANTITATIVE BETA-HUMAN CHORIONIC-GONADOTROPIN IN SCREENING FOR ECTOPIC PREGNANCY

被引:44
作者
STOVALL, TG
LING, FW
ANDERSEN, RN
BUSTER, JE
机构
[1] Department of Obstetrics and Gynecology, Division of Gynecology, University of Tennessee, Memphis, TN
[2] Department of Obstetrics and Gynecology, Division of Reproductive Endocrinology andInfertility, University of Tennessee, Memphis, TN
关键词
ECTOPIC PREGNANCY; HUMAN CHORIONIC GONADOTROPIN; PROGESTERONE;
D O I
10.1093/oxfordjournals.humrep.a137725
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The sensitivity and specificity of a single serum progesterone measurement was compared against two beta-human chorionic gonadotrophin (HCG) measurements 48 h apart in screening for abnormal pregnancy, i.e. ectopic pregnancy, completed or incomplete abortion. Of 1120 patients in the first trimester presenting with a positive urinary pregnancy test, 116/1120 (10.4%) had an ectopic pregnancy, 755/1120 (67.4%) had ultrasonographically confirmed intra-uterine pregnancies, and 249/1120 (22.2%) had abnormal intra-uterine pregnancies documented as complete, incomplete or missed abortions. Of the ectopic pregnancies, 113/116 (97.4%) had a serum progesterone level <25 ng/ml while 516/755 (68.3%) viable intra-uterine pregnancies had a serum progesterone level greater-than-or-equal-to 25 ng/ml. Of the 1120 patients screened, 402 (35.9%) had both a serum progesterone and two HCG measurements and were eligible for inclusion in this study. Setting a cut-off of 25 ng/ml, the sensitivity and specificity of a single serum progesterone measurement was then compared against two serial HCG measurements, utilizing receiver operating characteristic curves. This analysis demonstrated that a single serum progesterone measurement was significantly more sensitive (P < 0.05) than two HCG measurements in screening for an abnormal pregnancy. In some patients, a single serum progesterone makes possible the diagnosis of ectopic pregnancy 2 days earlier than two HCG determinations because a second blood sample was not required. We conclude that a single serum progesterone measurement should be added to serial HCG determinations as a standard diagnostic screening test for ectopic pregnancy.
引用
收藏
页码:723 / 725
页数:3
相关论文
共 12 条
[1]  
Beck J.R., Shultz E.K., The use of relative operative characteristic (ROC) curves in test performance evaluation, Arch. Pathol. Lab. Med, 110, pp. 13-17, (1986)
[2]  
Kadar N., Romero R., Observations on the log human chorionic gonadotropin-time relationship in early pregnancy and its practical implications, Am, J. Obstet. Gynecol, 157, pp. 73-78, (1987)
[3]  
Kadar N., Caldwell B.V., Romero R., A method of screening for ectopic pregnancy and its indications, Obstet. Gynecol, 58, pp. 162-166, (1981)
[4]  
Kadar N., Dechemey A.H., Romero R., Receiver operating characteristics (ROC) curve analysis of the relative efficacy of single and serial chorionic gonadotropin determinations in the early diagnosis of ectopic pregnancy, Fertil. Steril, 37, (1982)
[5]  
Matthews C.P., Goulson P.B., Wild R.A., Serum progesterone levels as an aid in the diagnosis of ectopic pregnancy, Obstet. Gynecol, 68, (1986)
[6]  
Milwidsky A., Segal S., Menasle M., Adoni A., Palti A., Corpus luteum function in ectopic pregnancy, Int, J. Fertil, 29, (1984)
[7]  
Pittaway D.E., Wentz A.C., Evaluation of early pregnancy by serial chorionic gonadotropin determinations: A comparison of methods by receiver operating characteristic curve analysis, Fertil. Steril, 43, (1985)
[8]  
Rad Wans Ka E., Frandenberg J., Allen E.L., Plasma progesterone levels in normal and abnormal early human pregnancy, Fertil. Steril, 30, pp. 398-402, (1978)
[9]  
Stovall T.G., Ling F.W., Cope B.J., Buster J.E., Preventing ruptured ectopic pregnancy with a single serum progesterone. Am, J. Obstet. Gynecol, 160, (1989)
[10]  
Stovall T.G., Kellerman L., Ling F.W., Buster J.E., Emergency department diagnosis of ectopic pregnancy, Ann. Emerg. Med, 19, pp. 1098-1103, (1990)