PINEAL AND PLASMA MELATONIN AS DETERMINED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION

被引:61
作者
VIEIRA, R
MIGUEZ, J
LEMA, M
ALDEGUNDE, M
机构
[1] Laboratorio de Fisioloxía Animal, Departamento de Fisioloxía, Facultade de Bioloxía
关键词
D O I
10.1016/0003-2697(92)90439-E
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive method for the routine quantitative determination of melatonin in pineal and plasma is described. The assay used reversed-phase high-performance liquid chromatography (RP-HPLC) separation combined with either amperometric (system A) or coulometric (system B) detection. The method gave satisfactory reproducibility and accuracy, and detection limits for melatonin were as low as 8.5 pg (system A) and 1 pg (system B). This high sensitivity, together with the short analysis time (less than 10 min), and the simplicity of sample procedure make the present RP-HPLC method suitable for a wide range of studies concerning melatonin measurements. Melatonin values obtained in this study from both rat pineal and human plasma agree with those reported previously, and clearly determined a circadian pattern. © 1992.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 23 条
  • [1] DETERMINATION OF INDOLES IN HUMAN AND RAT PINEAL
    ANDERSON, GM
    YOUNG, JG
    COHEN, DJ
    YOUNG, SN
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 228 (MAR): : 155 - 163
  • [2] CONCURRENT ONLINE SAMPLING OF MELATONIN IN PINEAL MICRODIALYSATES FROM CONSCIOUS RAT AND ITS ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    AZEKAWA, T
    SANO, A
    AOI, K
    SEI, H
    MORITA, Y
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (01): : 47 - 55
  • [3] BECKFRIIS J, 1985, PINEAL GLAND ENDOCRI, P313
  • [4] Binkley S, 1988, PINEAL ENDOCRINE NON
  • [5] MELATONIN IN HUMANS, NEUROENDOCRINOLOGICAL AND PHARMACOLOGICAL ASPECTS
    CLAUSTRAT, B
    BRUN, J
    CHAZOT, G
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 1990, 17 (07): : 625 - 632
  • [6] Ebadi M., 1984, P1
  • [7] FALLON A, 1987, APPLICATIONS HPLC BI
  • [8] DETERMINATION OF MELATONIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    GOLDMAN, ME
    HAMM, H
    ERICKSON, CK
    [J]. JOURNAL OF CHROMATOGRAPHY, 1980, 190 (01): : 217 - 220
  • [9] DETERMINATION OF PINEAL MELATONIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - APPLICATION FOR RHYTHM STUDIES AND TISSUE EXPLANTS
    HERNANDEZ, G
    ABREU, P
    ALONSO, R
    CALZADILLA, CH
    [J]. JOURNAL OF PINEAL RESEARCH, 1990, 8 (01) : 11 - 19
  • [10] Klein D. C., 1981, PINEAL GLAND, P199