NEAR-INFRARED SPECTROSCOPY AS AN ALTERNATIVE TO ASSESS COMPLIANCE OF AMPICILLIN-TRIHYDRATE WITH COMPENDIAL SPECIFICATIONS

被引:56
作者
PLUGGE, W [1 ]
VANDERVLIES, C [1 ]
机构
[1] GIST BROCADES BV,DEPT QUAL ASSURANCE,DIV IND PHARMACEUT PROD,POB 1,2600 MA DELFT,NETHERLANDS
关键词
PHARMACEUTICAL ANALYSIS; QUALITY CONTROL; NEAR-INFRARED SPECTROSCOPY; VALIDATION; AMPICILLIN TRIHYDRATE; CONFORMITY INDEX;
D O I
10.1016/0731-7085(93)80154-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of near-infrared spectroscopy (NIRs) as an alternative to several compendial test methods such as identification, water content and assay, in the release procedure of drug substances is demonstrated with ampicillin trihydrate as an example. It is also shown that in cases in which a manufacturing process is well under control, a 'standard activity' can be assigned to a batch when its conformity with 'standard quality' is proven by means of its NIR spectrum. For that purpose a new quality parameter - the Conformity Index (CI) - is introduced.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 16 条
[1]  
BRIK H, 1991, PHARMEUROPA, V3, P4
[2]   USES OF NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL ANALYSIS [J].
CIURCZAK, EW .
APPLIED SPECTROSCOPY REVIEWS, 1987, 23 (1-2) :147-163
[3]  
CIURCZAK EW, 1991, PHARM TECH, V15, P140
[4]  
CIURCZAK EW, 1990, SPECTROSC INT, V3, P39
[5]  
CIURZAK EW, 1991, SPECTROSCOPY INT, V3, P39
[6]  
CLANCY P, 1988, AM LAB, V20, P176
[7]  
CORTI P, 1990, ANALUSIS, V18, P117
[8]  
CORTI P, 1991, ANALUSIS, V19, P198
[9]  
CORTI P, 1989, PHARM ACTA HELV, V64, P140
[10]  
JENSEN R, 1988, Annales Pharmaceutiques Francaises, V46, P313