COMPLICATIONS OF THE WILTSE PEDICLE SCREW FIXATION SYSTEM

被引:69
作者
BLUMENTHAL, S [1 ]
GILL, K [1 ]
机构
[1] SW ORTHOPED INST,DALLAS,TX
关键词
PEDICLE SCREWS; SPINAL FUSION; COMPLICATION OF PEDICLE SCREWS;
D O I
10.1097/00007632-199310000-00024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of the current study is to retrospectively review the incidence and types of complications occurring using a single pedicle screw fixation system for lumbar spine fusions. For a 3-year period beginning in July 1987, 470 patients underwent spinal fusion and instrumentation with the Wiltse Pedicle Screw Fixation System. Although multiple configurations of the Wiltse System were included, the predominant construct was that of segmental pedicle screw fixation. Complications occurred in a total of 29 patients, for an overall complication rate of 6%. Among the complications were 10 wound problems (2%) that included 2 seromas requiring drainage and 3 superficial wound infections. The remaining five wound complications were deep wound infections requiring irrigation and debridement. The overall deep wound infection rate was 1%. Neurologic complications occurred in two patients, one with temporary foot drop and one with persistent L5 nerve root irritation confirmed by electromyogram (EMG). Both of these patients underwent anatomic workup, which failed to reveal any evidence of impingement by either screw or other hard tissue. Two intraoperative complications occurred, both involving fracture of the L5 pedicle. No adverse sequela resulted. There were 15 hardware complications, for an overall rate of 3%. This included four patients with broken screws (a total of eight screws). There were three failures at the screw-bone interface, as well as four patients with uncoupling of the screw rod linkage. In addition, there were four broken rods encountered. A total of 122 Wiltse devices were removed, for an overall removal rate of 25%. These were removed at an average of 10.5 months postoperatively, with a range of 7 weeks to 34 months. All fusions were explored at the time of hardware removal, and 111 of 122 fusions were judged successful in terms of achieving the goal of arthrodesis. The overall fusion rate was 91%. Based on the results of this study, it is thought that this method is both safe and efficacious when used appropriately.
引用
收藏
页码:1867 / 1871
页数:5
相关论文
共 6 条
[1]  
Boucher H.H., A method of spinal fusion, J Bone Joint Sure, 41B, (1959)
[2]  
Louis R., Fusion of the lumbar and sacral spine by internal fixation with screw plates, CORR, 203, pp. 18-33, (1986)
[3]  
Roy-Camille R., Saillant G., Mazel E., Internal fixation of the lumbar spine with pedicle screw plating, Clin Orthop, 203, pp. 7-17, (1986)
[4]  
Steffee A.D., Biscup R.S., Sitkowski D.J., Segmental spine plates with pedicle screw fixation, Clin Orthop, 203, pp. 45-53, (1986)
[5]  
West J.L., Ogilvie J.W., Bradford D.S., Complications of the variable screw plate fixation, Spine, 16, pp. 576-579, (1991)
[6]  
Zuckerman J., Hsv K., White A., Wynne G., Early results of spinal fusion using variable spine plating system, Spine, 13, pp. 570-579, (1988)