COMPARISON OF 4 METHODS FOR CALCULATING DIFFUSING-CAPACITY BY THE SINGLE-BREATH METHOD

被引:8
作者
BECK, KC
OFFORD, KP
SCANLON, PD
机构
[1] Mayo Clinic, S-3 Plummer Bldg, Rochester
关键词
D O I
10.1378/chest.105.2.594
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In 283 patients referred for testing in an outpatient pulmonary function laboratory, we studied the single-breath diffusing capacity of the lungs for carbon monoxide (Dco) using the Ogilvie (Og), Jones-Meade (JM), Epidemiological Standardization Project (ESP), and three-phase iterative methods (SPIT, similar to the three equation method). The Dco maneuvers were performed using automated equipment and American Thoracic Society (ATS) recommended procedures. There were small but significant differences in mean Dco, the ESP method yielding the largest, followed in order by JM, 3PIT, and Og methods. The SPIT and JM Dcos were in close agreement in all degrees and patterns of pulmonary function abnormality. The Og Dco method was G percent less than JM in patients with normal pulmonary function, although the difference was less in patients with expiratory flow limitation, restriction, or reduced Dco. There were no differences in the reproducibility of Dco measurements among the methods. Based on these results and a review of the literature, we conclude the following: (1) when measuring single-breath Dco using automated equipment that follows ATS recommended procedures for collecting a single expired gas sample of 500-ml volume, calculated Dco is largest using ESP method, following by JM, 3PIT, and Og methods; (2) in patients with reduced Dco associated with obstructive or restrictive abnormalities, the Og, 3PIT, and JM timing methods are nearly equivalent; and (3) reproducibility of Dco is the same by all methods.
引用
收藏
页码:594 / 600
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 1987, AM REV RESPIR DIS, V136, P1299
[2]   LUNG-FUNCTION TESTING - SELECTION OF REFERENCE VALUES AND INTERPRETATIVE STRATEGIES [J].
不详 .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (05) :1202-1218
[3]  
[Anonymous], 1987, Am Rev Respir Dis, V136, P1285
[4]  
FERRIS BG, 1978, AM REV RESPIR DIS, V118, P1
[5]   IMPROVED ACCURACY AND PRECISION OF SINGLE-BREATH CO DIFFUSING-CAPACITY MEASUREMENTS [J].
GRAHAM, BL ;
MINK, JT ;
COTTON, DJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (05) :1306-1313
[6]   A THEORETICAL-ANALYSIS OF THE SINGLE BREATH DIFFUSING-CAPACITY FOR CARBON-MONOXIDE [J].
GRAHAM, BL ;
DOSMAN, JA ;
COTTON, DJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (04) :221-227
[7]  
GRAHAM BL, 1984, AM REV RESPIR DIS, V129, P403
[8]  
HLASTALA MP, 1987, HDB PHYSL, P217
[9]   A THEORETICAL AND EXPERIMENTAL ANALYSIS OF ANOMALIES IN ESTIMATION OF PULMONARY DIFFUSING CAPACITY BY SINGLE BREATH METHOD [J].
JONES, RS ;
MEADE, F .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1961, 46 (02) :131-&
[10]  
LEECH JA, 1985, AM REV RESPIR DIS, V132, P1127