INFLUENCE OF OPERATOR-DEPENDENT AND PATIENT-DEPENDENT VARIABLES ON THE SUITABILITY OF AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY FOR ROUTINE CLINICAL USE

被引:36
作者
GURLEY, JC [1 ]
NISSEN, SE [1 ]
BOOTH, DC [1 ]
DEMARIA, AN [1 ]
机构
[1] LEXINGTON VET AFFAIRS MED CTR,LEXINGTON,KY
关键词
D O I
10.1016/0735-1097(92)90330-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was designed to elucidate the operator- and patient-dependent variables inherent in clinical application of quantitative coronary arteriography. Digital arteriograms from 25 consecutive patients undergoing diagnostic catheterization were analyzed by four experienced angiographers utilizing an automated coronary edge detection system to measure percent area stenosis. The identification of potentially significant lesions for quantitation constituted a major source of variability, with unanimous agreement on the presence of a greater-than-or-equal-to 50% stenosis occurring at 38 (29%) of the 130 reported sites. Selection of an optimal frame for quantitative analysis resulted in disagreement for every lesion reported. Frame selection by the operator, as opposed to measurement of preselected frames, increased the interobserver variability from 5% to 7% for automated geometric analysis (p < 0.01), and from 8% to 10.5% for automated densitometric analysis (p < 0.01). Fully automatic arterial border detection was possible for only 20 (52.5%) of the 38 unanimously identified stenoses. The 18 failures involved one or more of the following factors: 1) stenosis at a bifurcation (13 [72%]); 2) diffuse, severe disease (8 [44%]); 3) excessive vessel tortuosity or overlap or both (4 [22%]); and 4) poor image quality (5 [28%]). In contrast, the same automated border detection algorithm successfully traced all 15 preselected frames of discrete stenoses referred for coronary angioplasty. Automated quantitative coronary arteriography performs well when carefully selected, discrete stenoses are presented to the computer for analysis. However, quantitative analysis of routine clinical coronary arteriograms is limited by operator-dependent variability in stenosis identification and frame selection, as well as by complex coronary anatomy and suboptimal image quality. These limitations make automated quantitative coronary arteriography impractical for routine clinical use.
引用
收藏
页码:1237 / 1243
页数:7
相关论文
共 42 条
[1]   CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS [J].
ARNETT, EN ;
ISNER, JM ;
REDWOOD, DR ;
KENT, KM ;
BAKER, WP ;
ACKERSTEIN, H ;
ROBERTS, WC .
ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) :350-356
[2]   ACCURACY OF INDIVIDUAL AND PANEL VISUAL INTERPRETATIONS OF CORONARY ARTERIOGRAMS - IMPLICATIONS FOR CLINICAL DECISIONS [J].
BEAUMAN, GJ ;
VOGEL, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :108-113
[3]  
BOLLER A, 1989, ARCH MAL COEUR VAISS, V82, P381
[4]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[5]   COMPUTERIZED EDGE TRACKING AND LESION MEASUREMENT IN CORONARY ANGIOGRAMS - A PILOT-STUDY COMPARING SMOKERS WITH NON-SMOKERS [J].
CASHIN, WL ;
BROOKS, SH ;
BLANKENHORN, DH ;
SELZER, RH ;
SANMARCO, ME ;
BENJAUTHRIT, B .
ATHEROSCLEROSIS, 1984, 52 (03) :295-300
[6]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[7]   OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS [J].
DETRE, KM ;
WRIGHT, E ;
MURPHY, ML ;
TAKARO, T .
CIRCULATION, 1975, 52 (06) :979-986
[8]   REPRODUCIBILITY OF CORONARY ARTERIOGRAPHIC READING IN THE CORONARY-ARTERY SURGERY STUDY (CASS) [J].
FISHER, LD ;
JUDKINS, MP ;
LESPERANCE, J ;
CAMERON, A ;
SWAYE, P ;
RYAN, T ;
MAYNARD, C ;
BOURASSA, M ;
KENNEDY, JW ;
GOSSELIN, A ;
KEMP, H ;
FAXON, D ;
WEXLER, L ;
DAVIS, KB .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (06) :565-575
[9]   QUANTIFICATION OF CORONARY-ARTERY STENOSIS INVIVO [J].
GOULD, KL .
CIRCULATION RESEARCH, 1985, 57 (03) :341-353
[10]   PRESSURE-FLOW CHARACTERISTICS OF CORONARY STENOSES IN UNSEDATED DOGS AT REST AND DURING CORONARY VASODILATION [J].
GOULD, KL .
CIRCULATION RESEARCH, 1978, 43 (02) :242-253