MAINTENANCE OF COOLING-TOWERS FOLLOWING 2 OUTBREAKS OF LEGIONNAIRES-DISEASE IN A CITY

被引:15
作者
BHOPAL, RS [1 ]
BARR, G [1 ]
机构
[1] GLASGOW DIST COUNCIL,GLASGOW G1 1RN,SCOTLAND
关键词
D O I
10.1017/S0950268800054492
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This survey assessed the maintenance of evaporative cooling towers in Glasgow, following two Legionnaires' disease outbreaks. Information was obtained from 76 of 81 premises and a maintenance score was calculated for each of 174 towers. The quality of maintenance was extremely varied (range of maintenance scores, 8–30 mean, 22 (S. D., 5.0); median, 23; maximum possible, 33) and some towers were neglected. Breaches of maintenance principles were mainly structural and organizational, e.g. inadequate drift control, rather than failure to use chemicals. Low maintenance scores were associated with no log book, no guidelines, no change in procedures in last 5 years, solitary cooling towers, and towers on industrial premises. Despite intense publicity the standard of cooling tower maintenance in Glasgow remained a concern. Information campaigns directed at those responsible for cooling–tower maintenance are neccessary. © 1990, Cambridge University Press. All rights reserved.
引用
收藏
页码:29 / 38
页数:10
相关论文
共 21 条
  • [1] BARTLETT CLR, 1986, LEGIONELLA INFECTION
  • [2] BAXTER D, 1985, 9 MANCH U DEP COMM M
  • [3] BHOPAL RS, 1988, COMMUNICABLE DISEASE, V17, P7
  • [4] COOLING-TOWERS AND EVAPORATIVE CONDENSERS
    MILLER, RP
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 90 (04) : 667 - 670
  • [5] NORUSIS MJ, 1986, SPSS PC PLUS
  • [6] Siegel S., 1956, NONPARAMETRIC STAT B
  • [7] OUTBREAK OF LEGIONNAIRES-DISEASE IN GLASGOW-ROYAL-INFIRMARY - MICROBIOLOGICAL ASPECTS
    TIMBURY, MC
    DONALDSON, JR
    MCCARTNEY, AC
    FALLON, RJ
    SLEIGH, JD
    [J]. JOURNAL OF HYGIENE, 1986, 97 (03) : 393 - 403
  • [8] 1988, CONTROL LEGIONELLA H
  • [9] 1987, HN8716 DEP HLTH SOC
  • [10] 1986, HN8616 DEP HLTH SOC