DEVELOPMENT OF A 3-DIMENSIONAL FINITE-ELEMENT MODEL OF A HUMAN TIBIA USING EXPERIMENTAL MODAL-ANALYSIS

被引:37
作者
HOBATHO, MC
DARMANA, R
PASTOR, P
BARRAU, JJ
LAROZE, S
MORUCCI, JP
机构
[1] ECOLE NATL SUPER AERONAUT & ESPACE,F-31055 TOULOUSE,FRANCE
[2] INST NATL SCI APPL,F-31062 TOULOUSE,FRANCE
关键词
D O I
10.1016/0021-9290(91)90026-J
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The modal analysis of a human tibia consisted of characterizing its dynamic behavior by determining natural frequency, damping ratio and mode shapes. Two methods were used to perform the modal analysis: (1) a finite element method (structural model); (2) an experimental modal analysis (modal model). The experimental modal model was used to optimize the structural model. After optimization, differences in results between the two models were found to be due only to mechanical properties and mass distribution. The influences of boundary conditions and geometric properties (such as inertia and length) were eliminated by the finite element model itself. The percent relative error between the two methods was approximately 3%, corresponding to the standard deviation of the measured frequencies. For the frequency range considered, the mode shapes were bending modes in two different vibration planes (latero-medial and sagittal), with a slight torsion effect due to the twisted geometry of the tibia.
引用
收藏
页码:371 / &
相关论文
共 29 条
[1]  
ASHMAN RB, 1990, J BIOMECH, V22, P895
[2]   MECHANICAL STRENGTH OF TIBIAL TRABECULAR BONE EVALUATED BY X-RAY COMPUTED-TOMOGRAPHY [J].
BENTZEN, SM ;
HVID, I ;
JORGENSEN, J .
JOURNAL OF BIOMECHANICS, 1987, 20 (08) :743-&
[3]  
CIARELLI MJ, 1986, 32ND T ORTH RES SOC, P42
[4]  
COLLIER RJ, 1982, J BIOMECH, V8, P545
[5]   ASSESSMENT OF TIBIAL STIFFNESS BY VIBRATION TESTING INSITU .3. SENSITIVITY OF DIFFERENT MODES AND INTERPRETATION OF VIBRATION MEASUREMENTS [J].
CORNELISSEN, M ;
CORNELISSEN, P ;
VANDERPERRE, G ;
CHRISTENSEN, AB ;
AMMITZBOLL, F ;
DYRBYE, C .
JOURNAL OF BIOMECHANICS, 1987, 20 (04) :333-342
[6]  
Cornelissen M, 1988, MONITORING BONE COND, P79
[7]   ASSESSMENT OF TIBIAL STIFFNESS BY VIBRATION TESTING INSITU .2. INFLUENCE OF SOFT-TISSUES, JOINTS AND FIBULA [J].
CORNELISSEN, P ;
CORNELISSEN, M ;
VANDERPERRE, G ;
CHRISTENSEN, AB ;
AMMITZBOLL, F ;
DYRBYE, C .
JOURNAL OF BIOMECHANICS, 1986, 19 (07) :551-561
[8]   EVALUATION OF USE OF RESONANT FREQUENCIES TO CHARACTERIZE PHYSICAL-PROPERTIES OF HUMAN LONG BONES [J].
DOHERTY, WP ;
BOVILL, EG ;
WILSON, EL .
JOURNAL OF BIOMECHANICS, 1974, 7 (06) :559-&
[9]   RELATIONS OF COMPRESSIVE PROPERTIES OF HUMAN CORTICAL BONE TO HISTOLOGICAL STRUCTURE AND CALCIFICATION [J].
EVANS, FG ;
VINCENTELLI, R .
JOURNAL OF BIOMECHANICS, 1974, 7 (01) :1-+
[10]  
Ewins DJ., 1986, J VIB ACOUST, V108, P109, DOI [10.1115/1.3269294, DOI 10.1115/1.3269294]