ONLINE PRECONCENTRATION OF ALUMINUM WITH IMMOBILIZED 8-HYDROXYQUINOLINE FOR DETERMINATION BY ATOMIC-ABSORPTION SPECTROMETRY

被引:49
作者
MOHAMMAD, B
URE, AM
LITTLEJOHN, D
机构
[1] Department of Pure and Applied Chemistry, University of Strathclyde, Glasgow G1 1XL, Cathedral Street
关键词
ALUMINUM; RIVER AND SEA-WATER ANALYSIS; FLAME ATOMIC ABSORPTION SPECTROMETRY; ONLINE PRECONCENTRATION WITH 8-HYDROXYQUINOLINE;
D O I
10.1039/ja9920700695
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Knowledge of the chemistry of Al in solution, its behaviour under different pH conditions and its complexation with different buffering reagents has been used to devise and optimize an on-line preconcentration procedure for the determination of Al by flame atomic absorption spectrometry. A column of 8-hydroxyquinoline immobilized on controlled-pore glass is used to collect Al in a buffer of 0.1 mol dm-3 malonate at pH 10. The Al is eluted into the nebulizer of a dinitrogen oxide-acetylene flame with a mixture of 1 mol dm-3 HCl and 1 mol dm-3 HNO3. For a collection period of 3 min at a flow rate of 6 cm3 min-1, the detection limit is 3 ng cm-3 with an enrichment factor of 76. The method has been applied successfully to river and sea-waters.
引用
收藏
页码:695 / 699
页数:5
相关论文
共 29 条
[1]  
Baes CF., 1976, HYDROLYSIS CATIONS
[2]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[3]   RAPID SEPARATION OF TRACE-METALS FROM NEUTRON-ACTIVATED SALINE MATRICES BY CHELATION ON A POLY-5-VINYL-8-HYDROXYQUINOLINE COLUMN [J].
BUONO, JA ;
KARIN, RW ;
FASCHING, JL .
ANALYTICA CHIMICA ACTA, 1975, 80 (02) :327-334
[4]  
BURGESS J, 1978, METAL IONS SOLUTION, P265
[5]   AQUATIC ALUMINUM - CHEMISTRY, TOXICOLOGY, AND ENVIRONMENTAL PREVALENCE [J].
BURROWS, WD ;
HEM, JD .
CRC CRITICAL REVIEWS IN ENVIRONMENTAL CONTROL, 1977, 7 (02) :167-216
[6]  
CEDERGREN A, 1987, PURE APPL CHEM, V5, P221
[7]   FLOW-INJECTION ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF ALUMINUM BY ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
GARCIA, MRP ;
GARCIA, MED ;
MEDEL, AS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (07) :699-703
[8]   ONLINE ALUMINUM PRECONCENTRATION AND ITS APPLICATION TO THE DETERMINATION OF THE METAL IN DIALYSIS CONCENTRATES BY ATOMIC SPECTROMETRIC METHODS [J].
GARCIA, MRP ;
GARCIA, AL ;
GARCIA, MED ;
SANZMEDEL, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (01) :15-19
[9]   OPTIMIZATION OF THE ANALYTICAL CONDITIONS FOR THE DETERMINATION OF ALUMINUM IN HUMAN-BLOOD PLASMA AND SERUM BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY .2. ASSESSMENT OF THE ANALYTICAL METHOD [J].
GARDINER, PE ;
STOEPPLER, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (04) :401-404
[10]  
GREENWOOD NN, 1986, CHEM ELEMENTS, P252