MONOCLONAL-ANTIBODIES AGAINST HUMAN FIBROBLAST COLLAGENASE AND THE DESIGN OF AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY TO MEASURE TOTAL COLLAGENASE

被引:43
作者
CLARK, IM
POWELL, LK
WRIGHT, JK
CAWSTON, TE
HAZLEMAN, BL
机构
[1] Rheumatology Research Unit, Addenbrooke's Hospital, Cambridge, CB2 2QQ, Hills Road
来源
MATRIX | 1992年 / 12卷 / 06期
关键词
COLLAGENASE; ENZYME IMMUNOASSAY; MONOCLONAL ANTIBODY; POLYCLONAL ANTIBODY; TISSUE INHIBITOR OF METALLOPROTEINASES (TIMP);
D O I
10.1016/S0934-8832(11)80092-2
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Monoclonal antibodies have been raised against purified human fibroblast collagenase and characterised. One of these antibodies has been used in combination with a polyclonal anticollagenase antibody in a double antibody sandwich ELISA to measure collagenase. The assay range was 2-50 ng/ml collagenase. The assay measures total collagenase, i.e. pro-and active enzyme as well as collagenase in complex with TIMP. The level of collagenase has been measured in sera samples from patients with rheumatoid arthritis and compared with age- and sex-matched controls. The levels measured were: rheumatoid arthritis, 69 +/- 29 ng/ml; normal, 49 +/- 14 ng/ml.
引用
收藏
页码:475 / 480
页数:6
相关论文