TRIPLE-PENDULUM VIBRATION ISOLATION SYSTEM FOR A LASER INTERFEROMETER

被引:24
作者
TSUBONO, K
ARAYA, A
KAWABE, K
MORIWAKI, S
MIO, N
机构
[1] Department of Physics, University of Tokyo, Bunkyo
关键词
D O I
10.1063/1.1143967
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a triple-pendulum vibration isolation system for suspended mirrors used in a laser interferometer for gravitational wave detection. Owing to the passive damping method using high-performance permanent magnets, the system has a very simple, compact structure. We measured the isolation ratio for vibration below 40 Hz and confirmed that the observed and calculated values are in good agreement. The stability of the system has been demonstrated by operating a Michelson laser interferometer incorporated with a mirror mounted on the vibration isolation system.
引用
收藏
页码:2237 / 2240
页数:4
相关论文
共 9 条
  • [1] BLAIR DG, 1991, DETECTION GRAVITATIO
  • [2] 1ST RESULTS ON THE ELECTRONIC COOLING OF THE PISA SEISMIC NOISE SUPER-ATTENUATOR FOR GRAVITATIONAL-WAVE DETECTION
    BRADASCHIA, C
    DELFABBRO, R
    DIFIORE, L
    DIVIRGILIO, A
    GIAZOTTO, A
    KAUTZKY, H
    MONTELATICI, V
    PASSUELLO, D
    [J]. PHYSICS LETTERS A, 1989, 137 (7-8) : 329 - 333
  • [3] LOW-FREQUENCY BEHAVIOR OF THE PISA SEISMIC NOISE SUPER-ATTENUATOR FOR GRAVITATIONAL-WAVE DETECTION
    DELFABBRO, R
    DIVIRGILIO, A
    GIAZOTTO, A
    KAUTZKY, H
    MONTELATICI, V
    PASSUELLO, D
    [J]. PHYSICS LETTERS A, 1988, 133 (09) : 471 - 475
  • [4] Robertson NA., 1991, DETECTION GRAVITATIO, P353
  • [5] THE EQUIVALENCE OF INERTIAL AND PASSIVE GRAVITATIONAL MASS
    ROLL, PG
    KROTKOV, R
    DICKE, RH
    [J]. ANNALS OF PHYSICS, 1964, 26 (03) : 442 - 517
  • [6] THERMAL NOISE IN MECHANICAL EXPERIMENTS
    SAULSON, PR
    [J]. PHYSICAL REVIEW D, 1990, 42 (08): : 2437 - 2445
  • [7] NOISE BEHAVIOR OF THE GARCHING 30-METER PROTOTYPE GRAVITATIONAL-WAVE DETECTOR
    SHOEMAKER, D
    SCHILLING, R
    SCHNUPP, L
    WINKLER, W
    MAISCHBERGER, K
    RUDIGER, A
    [J]. PHYSICAL REVIEW D, 1988, 38 (02): : 423 - 432
  • [8] A DOUBLE PENDULUM VIBRATION ISOLATION SYSTEM FOR A LASER INTERFEROMETRIC GRAVITATIONAL-WAVE ANTENNA
    STEPHENS, M
    SAULSON, P
    KOVALIK, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (04) : 924 - 932
  • [9] Thorne K.S., 1987, 300 YEARS GRAVITATIO