ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS AS A PREDICTOR OF MECHANICAL LOOSENING OF KNEE PROSTHESES

被引:489
作者
RYD, L [1 ]
ALBREKTSSON, BEJ [1 ]
CARLSSON, L [1 ]
DANSGARD, F [1 ]
HERBERTS, P [1 ]
LINDSTRAND, A [1 ]
REGNER, L [1 ]
TOKSVIGLARSEN, S [1 ]
机构
[1] LUND UNIV, S-22100 LUND, SWEDEN
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1995年 / 77B卷 / 03期
关键词
D O I
10.1302/0301-620X.77B3.7744919
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The tibial components in 143 patients with total knee replacements performed before 1988 were assessed for micromotion using roentgen stereophotogrammetric analysis (RSA) over a period of 13 years. The fixation of the prostheses remained clinically sound in all cases, although revision had been required for other reasons in seven. In a second group taken from all cases with RSA available on our full database to 1990, 15 tibial components had been followed by RSA from the insertion until, 1 to 11 years after the initial arthroplasty, they were revised for mechanical loosening of the tibial component; 12 of these comprised all the loosenings in the base group, thus making a total of 155 consecutive cases, while an additional three were inserted after the base material had been compiled. The mean migration in the first group was about 1 mm at one year, but subsequent migration was slower, reaching a mean of about 1.5 mm after ten years, About one-third migrated continuously throughout follow-up, while two-thirds ceased to migrate after one to two years. In the revision group, 14 components had migrated continuously and at one year significantly more than those in the first group, One revision case lacked the crucial one-year follow-up and could not be classified. These findings suggest that mechanical loosening begins early in the postoperative period. Clinical symptoms which necessitate revision, seen at this stage in 20% of abnormally migrating tibial components, may not appear until up to ten years after the operation. RSA can be used at one to two years to identify prostheses 'at risk' of loosening with predictive power of about 85%.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 46 条
  • [1] RADIOLUCENT ZONE IN ARTHROPLASTY OF KNEE
    AHLBERG, A
    LINDEN, B
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (06): : 687 - 690
  • [2] Albrektsson B E, 1988, J Arthroplasty, V3, P145, DOI 10.1016/S0883-5403(88)80080-9
  • [3] THE EFFECT OF A STEM ON THE TIBIAL COMPONENT OF KNEE ARTHROPLASTY - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY OF UNCEMENTED TIBIAL COMPONENTS IN THE FREEMAN-SAMUELSON KNEE ARTHROPLASTY
    ALBREKTSSON, BEJ
    RYD, L
    CARLSSON, LV
    FREEMAN, MAR
    HERBERTS, P
    REGNER, L
    SELVIK, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02): : 252 - 258
  • [4] BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
  • [5] THE FIXATION OF A PROXIMAL TIBIAL POLYETHYLENE PROSTHESIS WITHOUT CEMENT
    BLAHA, JD
    INSLER, HP
    FREEMAN, MAR
    REVELL, PA
    TODD, RC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (03): : 326 - 335
  • [6] MICROMOTION OF THE TOTAL KNEE
    BROSTROM, LA
    GOLDIE, I
    SELVIK, G
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (04): : 443 - 445
  • [7] COOK SD, 1988, CLIN ORTHOP RELAT R, V230, P303
  • [8] Draenert K, 1981, Hip, P71
  • [9] ECKER ML, 1987, CLIN ORTHOP RELAT R, V216, P151
  • [10] EARLY MIGRATION AND LATE ASEPTIC FAILURE OF PROXIMAL FEMORAL PROSTHESES
    FREEMAN, MAR
    PLANTEBORDENEUVE, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03): : 432 - 438