Evaluating Clinical Accuracy of Continuous Glucose Monitoring Systems: Continuous Glucose - Error Grid Analysis (CG-EGA)

被引:21
作者
Clarke, William L. [1 ,2 ]
Anderson, Stacey [1 ,2 ]
Kovatchev, Boris [1 ,2 ]
机构
[1] Univ Virginia Sch Med, Dept Pediat Psychiat Med & Internal Med, Div Pediat Endocrinol Computat Neurosci, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Med, Dept Pediat Psychiat Med & Internal Med, Div Adult Endocrinol, Charlottesville, VA 22908 USA
关键词
Continuous Glucose monitoring; Continuous Glucose Error Grid Analysis; Clinical Accuracy;
D O I
10.2174/157339908785294389
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous Glucose Sensors (CGS) generate rich and informative continuous data streams which have the potential to improve the glycemic condition of the patient with diabetes. Such data are critical to the development of closed loop systems for automated glycemic control. Thus the numerical and clinical accuracy of such must be assured. Although numerical point accuracy of these systems has been described using traditional statistics, there are no requirements, as of yet, for determining and reporting the rate (trend) accuracy of the data generated. In addition, little attention has been paid to the clinical accuracy. of these systems. Continuous Glucose-Error Grid Analysis (CG-EGA) is the only method currently available for assessing the clinical accuracy of such data and reporting this accuracy for each of the relevant glycemic ranges, -hypoglycemia, euglycemia, hyperglycemia. This manuscript reviews the development of the original Error Grid Analysis (EGA) and describes its inadequacies when used to determine point accuracy of CGS systems. The development of CG-EGA as a logical extension of EGA for use with CGS is described in detail and examples of how it can be used to describe the clinical accuracy of several CGS are shown. Information is presented on how to obtain assistance with the use of CG-EGA.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 18 条
[1]   Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor [J].
Boyne, MS ;
Silver, DM ;
Kaplan, J ;
Saudek, CD .
DIABETES, 2003, 52 (11) :2790-2794
[2]  
Chen Ellen T, 2003, Diabetes Technol Ther, V5, P749, DOI 10.1089/152091503322526969
[3]  
Clarke William L, 2007, J Diabetes Sci Technol, V1, P669
[4]   Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis [J].
Clarke, WL ;
Anderson, S ;
Farhy, L ;
Breton, M ;
Gonder-Frederick, L ;
Cox, D ;
Kovatchev, B .
DIABETES CARE, 2005, 28 (10) :2412-2417
[5]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[6]   STABILITY OF REACTED CHEMSTRIP BG [J].
COX, D ;
HERRMAN, J ;
SNYDER, A ;
GONDERFREDERICK, L ;
RESCHKE, J ;
CLARKE, W .
DIABETES CARE, 1988, 11 (03) :288-291
[7]   ACCURACY OF PERCEIVING BLOOD-GLUCOSE IN IDDM [J].
COX, DJ ;
CLARKE, WL ;
GONDERFREDERICK, L ;
POHL, S ;
HOOVER, C ;
SNYDER, A ;
ZIMBELMAN, L ;
CARTER, WR ;
BOBBITT, S ;
PENNEBAKER, J .
DIABETES CARE, 1985, 8 (06) :529-536
[8]  
Feldman Ben, 2003, Diabetes Technol Ther, V5, P769, DOI 10.1089/152091503322526978
[9]  
Food and Drug Administration, 2006, SUMM SAF EFF DAT DEX
[10]  
Food and Drug Administration, 2006, SUMM SAF EFF DAT MED