ON THE SAGITTAL FOCUSING OF SYNCHROTRON RADIATION WITH A DOUBLE CRYSTAL MONOCHROMATOR

被引:32
作者
KUSHNIR, VI [1 ]
QUINTANA, JP [1 ]
GEORGOPOULOS, P [1 ]
机构
[1] NORTHWESTERN UNIV,ROBERT R MCCORMICK SCH ENGN & APPL SCI,DUNU SYNCHROTRON RES CTR,EVANSTON,IL 60201
关键词
D O I
10.1016/0168-9002(93)90679-C
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A method to avoid the anticlastic bending of the second crystal in a two-crystal monochromator for synchrotron radiation is proposed. It is analytically shown that the anticlastic curvature is zero at the center of the crystal for a simply supported isotropic crystal loaded with a constant moment provided that the crystal's aspect ratio is equal to a ''golden value'' dependent on the Poisson coefficient nu. For nu = 0.262 (equal to nu in the Si(111) plane) this ratio is 2.360. Finite element results are presented on the case of the clamped crystal and show that there is a similar ''golden value'' approximately equal to 1.42 for nu = 0.262.
引用
收藏
页码:588 / 591
页数:4
相关论文
共 9 条
[1]   SAGITTAL FOCUSING OF SYNCHROTRON RADIATION [J].
BATTERMAN, BW ;
BERMAN, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3) :327-331
[2]   EVALUATION OF THE ANTICLASTIC CURVATURE OF ELASTICALLY BENT CRYSTALS FOR X-RAY FOCUSING OPTICS [J].
FERRER, S ;
KRISCH, M ;
DEBERGEVIN, F ;
ZONTONE, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (03) :444-447
[3]   A SIMPLE SAGITTAL FOCUSING CRYSTAL WHICH UTILIZES A BIMETALLIC STRIP [J].
KNAPP, GS ;
RAMANATHAN, M ;
NIAN, HL ;
MACRANDER, AT ;
MILLS, DM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :465-467
[4]   SAGITTALLY FOCUSING DOUBLE-CRYSTAL MONOCHROMATOR WITH CONSTANT EXIT BEAM HEIGHT AT THE PHOTON FACTORY [J].
MATSUSHITA, T ;
ISHIKAWA, T ;
OYANAGI, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :377-379
[5]   A FIXED EXIT SAGITTAL FOCUSING MONOCHROMATOR UTILIZING BENT SINGLE-CRYSTALS [J].
MILLS, DM ;
HENDERSON, C ;
BATTERMAN, BW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :356-359
[6]   X-RAY MONOCHROMATOR GEOMETRY FOR FOCUSING SYNCHROTRON RADIATION ABOVE 10 KEV [J].
SPARKS, CJ ;
BORIE, BS ;
HASTINGS, JB .
NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2) :237-242
[7]  
SPARKS CJ, 1982, NUCL INSTRUM METHODS, V194, P73
[8]  
Timoshenko S., 1959, THEORY PLATES SHELLS, p[82, 87]
[9]   YOUNGS MODULUS SHEAR MODULUS AND POISSONS RATIO IN SILICON AND GERMANIUM [J].
WORTMAN, JJ ;
EVANS, RA .
JOURNAL OF APPLIED PHYSICS, 1965, 36 (01) :153-+