QUANTITATIVE-DETERMINATION OF SELECTED COMPOUNDS IN A KENTUCKY-1R4F REFERENCE CIGARETTE-SMOKE BY MULTIDIMENSIONAL GAS-CHROMATOGRAPHY AND SELECTED ION MONITORING MASS-SPECTROMETRY

被引:29
作者
WHITE, EL
UHRIG, MS
JOHNSON, TJ
GORDON, BM
HICKS, RD
BORGERDING, MF
COLEMAN, WM
ELDER, JF
机构
[1] R.J. Reynolds Tobacco Company, Bowman Gray Technical Center, Winston-Salem, NC
关键词
D O I
10.1093/chromsci/28.8.393
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Eight compounds from a Kentucky 1R4F reference cigarette smoke condensate have been determined by selected ion monitoring-mass spectrometry (SIM-MS) to confirm the validity of multidimensional gas chromatography (MDGC) as a quantitative tool in complex mixture analyses. Four electrostatically precipitated smoke condensate samples of 100 cigarettes each are dissolved individually in 25 mL of 2-propanol. The 2-propanol contains two methylesters (C8and C14) and seven deuterium-labeled compounds used as internal standards (IS). Analysis of the compounds of interest, pyridine; acetamide; acrylamide; phenol; o-, m-, and p-cresol; and quinoline, is accomplished by using two heartcuts. Heartcut times of the MDGC analysis are selected such that at least one IS is transferred with each group of compounds being analyzed. This study shows that the MDGC technique previously developed and described can be used for quantitative analyses. A comparison is made between the two types of internal standards. The results obtained for both types of internal standards agree within 20% of each other, on the average, with higher standard deviations for approximately 60% of the compounds where methyl esters are used as internal standards. © 1990 Oxford University Press.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 23 条
[1]   HYDROCARBON GROUP-TYPE ANALYSES BY ONLINE MULTI-DIMENSIONAL CHROMATOGRAPHY .2. LIQUID-CHROMATOGRAPHY GAS-CHROMATOGRAPHY [J].
APFFEL, JA ;
MCNAIR, H .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :139-144
[2]  
BEYER WH, 1968, CRC STANDARD MATH TA
[3]   CHARACTERIZATION OF BIO-POLYMERS BY PYROLYSIS-GAS CHROMATOGRAPHY AND MULTIDIMENSIONAL-ANALYSIS - APPLICATION TO SYNTHETIC MELANINS [J].
CHARMAN, WNA ;
FARQUHAR, CJ ;
FINNIN, BC ;
REED, BL .
JOURNAL OF CHROMATOGRAPHY, 1987, 388 (02) :389-396
[4]   MULTIDIMENSIONAL GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION FOR THE DETERMINATION OF TOXIC CONGENERS IN POLYCHLORINATED BIPHENYL MIXTURES [J].
DUINKER, JC ;
SCHULZ, DE ;
PETRICK, G .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :478-482
[5]   COMPLEX MIXTURE ANALYSIS BY CAPILLARY-TO-CAPILLARY COLUMN HEARTCUTTING GC/MS [J].
ELDER, JF ;
GORDON, BM ;
UHRIG, MS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (01) :26-33
[6]  
GORDON BM, 1985, J CHROMATOGR SCI, V23, P1
[7]   ANALYSIS OF FLUE-CURED TOBACCO ESSENTIAL OIL BY HYPHENATED ANALYTICAL TECHNIQUES [J].
GORDON, BM ;
UHRIG, MS ;
BORGERDING, MF ;
CHUNG, HL ;
COLEMAN, WM ;
ELDER, JF ;
GILES, JA ;
MOORE, DS ;
RIX, CE ;
WHITE, EL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (04) :174-180
[8]  
GORDON BWF, UNPUB
[9]  
HUBER JFK, 1979, J CHROMATOGR, V172, P15, DOI 10.1016/S0021-9673(00)90941-5
[10]  
JOHANSEN NG, 1984, J HIGH RES CHROMATOG, V7, P487, DOI 10.1002/jhrc.1240070809