AN ELISA FOR ELASTASE ALPHA-1-PROTEASE INHIBITOR COMPLEXES IN HUMAN PLASMA AND SERUM

被引:12
作者
ANTONSEN, S
WANSCHER, M
机构
[1] ODENSE UNIV HOSP, DEPT CLIN CHEM, DK-5000 ODENSE, DENMARK
[2] ODENSE UNIV HOSP, DEPT ANESTHESIOL, DK-5000 ODENSE, DENMARK
关键词
DETECTION LIMIT; GRANULOCYTES; NEUTROPHILS; REFERENCE INTERVAL;
D O I
10.3109/00365519309088401
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
An ELISA for neutrophil elastase (ELA) in complex with alpha1-protease inhibitor (PI) (alpha1-antitrypsin) was developed in microtitre plates and compared to the ELISA kit from MERCK (2-h version). Recovery of ELA-PI was good in both assays. The detection limits were 4.4 mug l-1 and 7.7 mug l-1 of the in-house and MERCK assay, respectively, while limits of quantitation were estimated to 7.7 mug l-1 (5.5-9.9 mug l-1) and 28.9 mug l-1 (14.6-44.3 mug l-1) for the two assays. Furthermore, as dilution curves of normal plasma were parallel with the calibration curve in the in-house assay over a wide range of dilutions, it is feasible to assay plasma in dilutions of only 1 : 6, resulting in a limit of quantitation of only 1.1 mug l-1. The total analytical coefficient of variation for samples measured in double determinations was 10.5%-12.5% in the in-house assay and 13.9%-14.6% in the MERCK assay. One-hundred-and-eight plasma samples covering a wide range of ELA-PI concentrations were analysed in both assays. A proportional difference between the two methods was detected, the mean ratio (in-house/MERCK) with 95% confidence limits was 1.115 (1.070-1.160). The cause of the difference was probably due to different calibration of the assays. Until this problem is solved, method specific reference intervals are needed. A reference interval for the in-house method based on plasma samples from 123 healthy adults; median age 36 years (range: 19-65 years) was estimated to 16.5-48.5 mug l-1.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 34 条
  • [1] MOLECULAR-DISTRIBUTION OF ELASTASE BETWEEN ITS 2 MAIN INHIBITORS - DIRECT QUANTITATION OF ELASTASE-ALPHA-2-MACROGLOBULIN COMPLEX WITH A NOVEL ELISA TECHNIQUE
    ADEYEMI, EO
    HODGSON, HJF
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (04) : 433 - 440
  • [2] CIRCULATING HUMAN-LEUKOCYTE ELASTASE IN PATIENTS WITH INFLAMMATORY BOWEL-DISEASE
    ADEYEMI, EO
    NEUMANN, S
    CHADWICK, VS
    HODGSON, HJF
    PEPYS, MB
    [J]. GUT, 1985, 26 (12) : 1306 - 1311
  • [3] ADEYEMI EO, 1990, BRIT J RHEUMATOL, V29, P15
  • [4] NEUTROPHIL LYSOSOMAL-ENZYME RELEASE AND COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS
    ANTONSEN, S
    BRANDSLUND, I
    CLEMENSEN, S
    SOFELDT, S
    MADSEN, T
    ALSTRUP, P
    [J]. SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1987, 21 (01): : 47 - 52
  • [5] ANTONSEN S, SCAND J CLIN LAB INV, P133
  • [6] MEASUREMENT OF PLASMA-CONCENTRATIONS OF POLYMORPHONUCLEAR ELASTASE-ALPHA-1 PROTEINASE-INHIBITOR (ELASTASE-ALPHA-1 ANTITRYPSIN) IN PATIENTS WITH RHEUMATOID-ARTHRITIS - INTERFERENCE BY RHEUMATOID-FACTOR
    BANKS, RE
    EVANS, SW
    TAYLOR, KF
    BIRD, HA
    WHICHER, JT
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1990, 49 (01) : 18 - 21
  • [7] BOGER C, 1988, J CLIN CHEM CLIN BIO, V26, P645
  • [8] BOXER LA, 1988, HEMATOL ONCOL CLIN N, V2, P101
  • [9] BROWER MS, 1983, BLOOD, V61, P842
  • [10] Buttner J, 1979, Clin Chim Acta, V98, p129F