RABBIT PNEUMOTHORAX - FEASIBILITY OF AN ANIMAL-MODEL TO SIMULATE NEONATAL PNEUMOTHORAX

被引:2
作者
DON, S [1 ]
COHEN, MD [1 ]
KRUGER, RA [1 ]
WINKLER, TA [1 ]
KATZ, BP [1 ]
LI, W [1 ]
DREESEN, G [1 ]
KENNAN, N [1 ]
TARVER, R [1 ]
KLATTE, EC [1 ]
机构
[1] INDIANA UNIV,MED CTR,JAMES WHITCOMB RILEY HOSP CHILDREN,DEPT MED,DIV BIOSTAT,INDIANAPOLIS,IN
关键词
COMPUTED RADIOGRAPHY; FILM-SCREEN RADIOGRAPHY; NEONATE; PNEUMOTHORAX;
D O I
10.1097/00004424-199405000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The feasibility of developing an animal model to simulate radiographic features of neonatal pneumothorax was investigated, and supine computed radiography (CR) and film-screen radiography (FS) images were compared. METHODS. 5-Fr pigtail catheters were inserted into the right pleural space of three New Zealand white rabbits. Two CR and two FS supine images were obtained using identical technique. After serial 4-mL injections of air, one CR and one FS supine image were obtained. The images were masked and randomized, and four radiologists reviewed the images for typical signs of pneumothorax. Chest computed tomography (CT) was performed before the injection of any air and after completion of the study. RESULTS. At zero-mL air volume, radiologists did not perceive a pneumothorax. As the air volume increased, the number of signs of a pneumothorax increased; there was no significant difference between CR and FS in the number of signs of pneumothorax detected at any volume. Chest CT confirmed that there was no unexplained air leak. The volume of air injected correlated with the calculated volume from the CT. CONCLUSIONS. This induced, volume-controlled, animal model simulated the supine radiographic features of neonatal pneumothorax.
引用
收藏
页码:558 / 563
页数:6
相关论文
共 14 条
[1]  
BRODERICK NJ, 1988, 1988 SOC PED RAD ANN
[2]  
BRODERICK NJ, 1989, MAY EUR SOC PED RAD
[3]   PNEUMOTHORAX - RADIOLOGIC TREATMENT WITH SMALL CATHETERS [J].
CASOLA, G ;
VANSONNENBERG, E ;
KEIGHTLEY, A ;
HO, M ;
WITHERS, C ;
LEE, AS .
RADIOLOGY, 1988, 166 (01) :89-91
[4]  
CHASLER CN, 1964, AMER J ROENTGENOL RA, V91, P550
[5]   DIGITAL IMAGING WITH A PHOTOSTIMULABLE PHOSPHOR IN THE CHEST OF NEWBORNS [J].
COHEN, MD ;
KATZ, BP ;
KALASINSKI, LA ;
WHITE, SJ ;
SMITH, JA ;
LONG, B .
RADIOLOGY, 1991, 181 (03) :829-832
[6]   COMPARISON OF A PACS WORKSTATION WITH CONVENTIONAL FILM FOR INTERPRETATION OF NEONATAL EXAMINATIONS - A PAIRED COMPARISON STUDY [J].
FRANKEN, EA ;
SMITH, WL ;
BERBAUM, KS ;
KAO, SCS ;
SATO, Y .
PEDIATRIC RADIOLOGY, 1991, 21 (05) :336-340
[7]  
GREGORY GA, 1982, PEDIATRICS, P1408
[8]  
KIRKS DR, 1984, PRACTICAL PEDIATRIC, P445
[9]   NEW PIGTAIL CATHETER FOR PLEURAL DRAINAGE IN PEDIATRIC-PATIENTS [J].
LAWLESS, S ;
ORR, R ;
KILLIAN, A ;
EGAR, M ;
FUHRMAN, B .
CRITICAL CARE MEDICINE, 1989, 17 (02) :173-175
[10]  
MCLAUGHLIN CA, 1979, LABORATORY ANATOMY R, P38