INFLUENCE OF CONE DESIGN ON THE ELECTRON-BEAM CHARACTERISTICS ON CLINICAL ACCELERATORS

被引:19
作者
KASSAEE, A
ALTSCHULER, MD
AYYALSOMAYAJULA, S
BLOCH, P
机构
[1] University of Pennsylvania Medical Center, Department of Radiation Oncology, Philadelphia, Pennsylvania 19104
关键词
ELECTRON BEAM; CONE DESIGN; LINEAR ACCELERATOR; DOSIMETRY; LEAKAGE RADIATION;
D O I
10.1118/1.597280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electron beam characteristics were investigated for different applicator cone designs. Low-energy scattered electrons from the cone housing can contribute to the skin dose. The depth dose was measured as a function of electron energies and field size for different cones. The measurements were compared with calculated 3-D dose distributions obtained from Monte-Carlo-derived energy deposition kernels [Phys. Med. Biol. 37, 391 (1992)]. This comparison shows that beam-defining cones can be fabricated to eliminate low-energy scattered electrons from the cone housing. Eliminating low-energy electrons from the cones provides depth dose (DD) characteristics for clinical electron beams that are comparable to those (1) from nearly monoenergetic electrons (as determined from the practical range of the electrons), and (2) for which the DD is nearly independent of source-to-skin distance. Measurements of DD for small circular fields were also performed. For very small field sizes, corresponding to the width of the lateral spread of a pencil beam, the theoretical and measured DD were found to depend on field size. Three-dimensional dose calculations of small and irregularly shaped electron fields are necessary to appreciate these effects. © 1994, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1671 / 1676
页数:6
相关论文
共 10 条
[1]   3D DOSE CALCULATIONS FOR ELECTRON AND PHOTON BEAMS [J].
ALTSCHULER, MD ;
BLOCH, P ;
BUHLE, EL ;
AYYALASOMAYAJULA, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :391-411
[2]   LEVELS OF LEAKAGE RADIATION FROM ELECTRON COLLIMATORS OF A LINEAR-ACCELERATOR [J].
DAS, KR ;
CRAMB, JA ;
MILLAR, RM ;
KENNY, MB ;
PATTERSON, WR ;
ACKERLY, TL ;
PERKINS, AE ;
CHONGKITIVITYA, K .
MEDICAL PHYSICS, 1990, 17 (06) :1058-1063
[3]  
HALBEIB JA, 1984, SAND840573
[4]  
HOGSTROM KR, 1992, ADV RAD ONCOLOGY PHY
[5]   RADIATION LEAKAGE FROM LINAC ELECTRON APPLICATOR ASSEMBLY [J].
KEYS, RA ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (05) :713-721
[6]  
KHAN FM, 1987, RAD ONCOLOGY PHYSICS
[7]   LEAKAGE RADIATION FROM ELECTRON APPLICATORS ON A MEDICAL ACCELERATOR [J].
PENNINGTON, EC ;
JANI, SK ;
WEN, BC .
MEDICAL PHYSICS, 1988, 15 (05) :763-765
[8]   RADIATION LEAKAGE FROM ELECTRON APPLICATOR ASSEMBLY ON A LINEAR-ACCELERATOR [J].
SCHNEIDER, AJ .
MEDICAL PHYSICS, 1982, 9 (05) :761-762
[9]   A NEW MODEL FOR COMPUTERIZED CLINICAL ELECTRON-BEAM DOSIMETRY [J].
VANDEGEIJN, J ;
CHIN, B ;
POCHOBRADSKY, J ;
MILLER, RW .
MEDICAL PHYSICS, 1987, 14 (04) :577-584
[10]   ALOPECIA ASSOCIATED WITH UNEXPECTED LEAKAGE FROM ELECTRON CONE [J].
WEN, BC ;
PENNINGTON, EC ;
HUSSEY, DH ;
JANI, SK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1637-1641