THE LOCAL-REGULATION OF BLOOD-FLOW EVALUATED SIMULTANEOUSLY BY 133-XENON WASHOUT AND LASER DOPPLER FLOWMETRY

被引:16
作者
ENGELHART, M
PETERSEN, LJ
KRISTENSEN, JK
机构
[1] BISPEBJERG HOSP, DEPT DERMATOL, 23 BISPEBJERG BAKKE, DK-2400 COPENHAGEN, DENMARK
[2] UNIV COPENHAGEN, RIGSHOSP, DEPT DERMATOL, DK-2100 COPENHAGEN, DENMARK
关键词
D O I
10.1111/1523-1747.ep12476572
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The laser Doppler flowmeter the 133-Xenon washout techniques of measuring cutaneous blood flow were compared for measuring the vasoconstrictor response of the hand during orthostatic maneuvres. Important discrepancies were detected for the two methods. When the hand was lowered by 40 cm a 40% decrease in blood flow was detected by the 133-Xenon method, while a 60% decrease was seen by the laser Doppler technique. Lowering the hand by 50 cm resulted in no further blood flow decrease when using the 133-Xenon method, but an 80% blood flow decrease was recorded with the laser Doppler method. A marked decrease in blood flow was recorded by the laser Doppler technique in hands that were sympathectomized or a hand that was subjected to a nerve blocade, strategies which should eliminate the orthostatic vasoconstrictor response of superficial cutaneous vessels. The 133-Xenon technique did not detect any blood flow changes in hands without sympathetic tone. We found the laser Doppler flowmetry technique unsatisfactory for measurement of blood flow changes that occur in nutritional vessels as this method measures total skin blood flow including non-capillary vessels.
引用
收藏
页码:451 / 453
页数:3
相关论文
共 11 条
[1]  
ENGELHART M, 1986, CLIN PHYSIOL, V6, P481
[2]   EVALUATION OF CUTANEOUS BLOOD-FLOW RESPONSES BY XE-133 WASHOUT AND A LASER-DOPPLER FLOWMETER [J].
ENGELHART, M ;
KRISTENSEN, JK .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1983, 80 (01) :12-15
[3]   EFFECT OF CHRONIC SYMPATHETIC DENERVATION UPON LOCAL REGULATION OF BLOOD-FLOW IN HUMAN SUBCUTANEOUS TISSUE [J].
HENRIKSEN, O .
ACTA PHYSIOLOGICA SCANDINAVICA, 1976, 97 (03) :377-384
[4]  
HENRIKSEN O, 1980, ACTA CHIR SCAND, P63
[5]   A COMPARISON BETWEEN XE-133 WASHOUT TECHNIQUE AND LASER DOPPLER FLOWMETRY IN THE MEASUREMENT OF LOCAL VASOCONSTRICTOR EFFECTS ON THE MICROCIRCULATION IN SUBCUTANEOUS TISSUE AND SKIN [J].
KASTRUP, J ;
BULOW, J ;
LASSEN, NA .
CLINICAL PHYSIOLOGY, 1987, 7 (05) :403-409
[6]  
KETY SS, 1951, PHARMACOL REV, V3, P1
[7]  
KRISTENSEN JK, 1983, ACTA DERM-VENEREOL, V63, P43
[8]   EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[9]  
OBERG PA, 1984, ACTA MED SCAND, P17
[10]  
SEJRSEN P, 1971, DAN MED BULL, V18, P1