THE ROLE OF FLOW-INJECTION ANALYSIS WITHIN THE FRAMEWORK OF AN AUTOMATED LABORATORY

被引:7
作者
STOCKWELL, PB
机构
[1] P S Analytical Ltd, Kernsing, Sevenoaks, Kent TN15 6QY, Arthur House, B4 Chaucer Business Park, Watery Lane
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1990年 / 12卷 / 03期
关键词
D O I
10.1155/S1463924690000116
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow Injection Analysis (FIA) was invented at roughly the same time by two quite dissimilar research groups [1,2]. FIA was patented by both groups in 1974; a year also marked by the publication of the first book on automatic chemical analysis [3]. This book was a major undertaking for its authors and it is hoped that it has added to the knowledge of those analysts attempting to automate their work or to increase the level of computerization/automation and thus reduce staffing commitments. This review discusses the role of FIA in laboratory automation, the advantages and disadvantages of the FIA approach, and the part it could play in future developments. It is important to stress at the outset that the FIA approach is all too often closely paralleled with convention al continuous flow analysis (CFA). This is a mistake for many reasons, none the least of which because of the considerable success of the CFA approach in contrast to the present lack of penetration in the commercial market-place of FIA instrumentation. © 1990, Hindawi Publishing Corporation. All rights reserved.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 41 条
[1]   EVALUATION OF BCDE, A MICROCOMPUTER PROGRAM TO ANALYZE AUTOMATED BLOOD COUNTS AND DIFFERENTIALS [J].
BATES, JE ;
BESSMAN, JD .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (03) :314-323
[2]   PLATELET SIZE IN HEALTH AND HEMATOLOGIC DISEASE [J].
BESSMAN, JD ;
WILLIAMS, LJ ;
GILMER, PR .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1982, 78 (02) :150-153
[3]  
BESSMAN JD, 1983, AM J CLIN PATHOL, V80, P242
[4]  
BETTERIDGE D, 1983, ANAL CHEM, V55, P2258
[5]  
BRENNAN MC, 1990, IN PRESS J AUTOMATIC
[6]   LEAD PRECONCENTRATION WITH FLOW-INJECTION FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
BYSOUTH, SR ;
TYSON, JF ;
STOCKWELL, PB .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :329-337
[7]   EVALUATION OF THE SYSMEX CC-800 - AN AUTOMATED 8-PARAMETER HEMATOLOGY INSTRUMENT [J].
CARLSON, DA ;
ITO, RK ;
STATLAND, BE ;
DAIGNEAULT, R ;
DIPIERRO, R ;
HORION, L .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1986, 86 (01) :55-60
[8]  
CARTER JM, 1970, ANALYST, V11, P148
[9]  
CHARACHE S, 1985, ARCH INTERN MED, V145, P1582
[10]   ON THE INDUCTION OF DEPRESSED MOOD IN THE LABORATORY - EVALUATION AND COMPARISON OF THE VELTEN AND MUSICAL PROCEDURES [J].
CLARK, DM .