A SIMPLER, SAFER, HIGHER PERFORMANCE COOLING SYSTEM ARRANGEMENT FOR WATER-COOLED DIVERTORS

被引:4
作者
CARELLI, MD
KOTHMANN, RE
GREEN, L
ZHAN, NJ
STEFANI, F
ROIDT, RM
机构
来源
FUSION TECHNOLOGY | 1994年 / 26卷 / 03期
关键词
D O I
10.13182/FST94-A40224
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A cooling system arrangement is presented which is specifically designed for high heat flux water cooled diverters. The motivation behind the proposed ''unichannel'' configuration is to provide maximum safety; this design eliminates flow instabilities liable to occur in parallel channel designs, it eliminates total blockage, it promotes cross flow to counteract the effects of partial blockage and/or local hot spots, and it is much more tolerant to the effects of debonding between the beryllium armor and the copper substrate. Added degrees of freedom allow optimization of the design, including the possibility of operating at very high heat transfer coefficients associated with nucleate boiling, while at the same time providing ample margin against departure from nucleate boiling. Projected pressure drop, pumping power, and maximum operating temperatures are lower than for conventional parallel channel designs.
引用
收藏
页码:611 / 617