A RADIOGRAPHIC COMPARISON OF 2 ROOT-CANAL INSTRUMENTATION TECHNIQUES

被引:36
作者
BACKMAN, CA
OSWALD, RJ
PITTS, DL
机构
关键词
D O I
10.1016/S0099-2399(06)81137-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The ability of two instrumentation techniques to negotiate and enlarge small curved canals was com-compared radiographically. Fifty canals in extracted human molar teeth were instrumented by the progressive enlargement (PE) technique, a form of step-back preparation using standard K files, or by the balanced force (BF) technique using K files whose tips had been specially modified. By using drawings and projected radiographic images of the files, the position of the largest file used in the apical preparation, #30 or #35 for the PE technique and #45 for the BF technique, was compared with the position of a small file placed in the canal before instrumentation. The PE and BF techniques were equally capable of instrumenting small curved canals to their respective largest apical preparation sizes. However, at sizes equivalent to the largest apical preparation sizes used in the PE technique, the BF technique produced significantly less deviation from the center of the original canal.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 13 条
[1]  
[Anonymous], STATISTICAL PACKAGE
[2]  
INGLE JI, 1985, ENDODONTICS, P195
[3]  
MULLANEY TP, 1979, DENT CLIN N AM, V23, P575
[4]  
OSWALD RJ, 1979, DENT CLIN N AM, V23, P593
[5]  
OSWALD RJ, 1987, COURSE ENDODONTIC TE, P81
[6]   A COMPARISON OF THE EFFECT OF MODIFIED AND NONMODIFIED INSTRUMENT TIPS ON APICAL CANAL CONFIGURATION [J].
POWELL, SE ;
SIMON, JHS ;
MAZE, BB .
JOURNAL OF ENDODONTICS, 1986, 12 (07) :293-300
[7]   THE BALANCED FORCE CONCEPT FOR INSTRUMENTATION OF CURVED CANALS [J].
ROANE, JB ;
SABALA, CL ;
DUNCANSON, MG .
JOURNAL OF ENDODONTICS, 1985, 11 (05) :203-211
[8]  
ROANE JB, 1979, ENDODONTICS SINGLE V, P30
[9]  
SCHILDER H, 1974, DENT CLIN N AM, V18, P269
[10]  
Schilder H., 1984, PATHWAYS PULP, P175