DEVELOPMENT OF AN ELECTRONICALLY TUNABLE L-BAND RESONATOR FOR EPR SPECTROSCOPY AND IMAGING OF BIOLOGICAL SAMPLES

被引:32
作者
CHZHAN, M
KUPPUSAMY, P
ZWEIER, JL
机构
[1] JOHNS HOPKINS MED INST,DEPT MED,DIV CARDIOL,CELLULAR BIOPHYS LAB,BALTIMORE,MD 21224
[2] JOHNS HOPKINS MED INST,ELECTRON PARAMAGNET RESONANCE CTR,BALTIMORE,MD 21224
来源
JOURNAL OF MAGNETIC RESONANCE SERIES B | 1995年 / 108卷 / 01期
关键词
D O I
10.1006/jmrb.1995.1103
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
While interest in the EPR spectroscopy and imaging of biological samples triggered the development of numerous resonator and microwave-bridge designs operating at high RF and L-band frequencies, a number of important technical problems remain, Two of these problems are the occurrence of sample-induced drifts in resonance frequency of the resonator and the intrinsic limitations in sensitivity of low-frequency EPR measurements, In an effort to address these problems, an approach was developed for obtaining fixed-frequency EPR measurements, utilizing a low-phase-noise fixed-frequency oscillator as a microwave source and an electronically tunable ceramic re-entrant L-band resonator, which was locked to the oscillator via automatic frequency control (AFC). The tunable microwave resonator described in this paper employs a voltage-controlled piezoelectric actuator for adjustment of the resonance frequency via variations of the equivalent capacitance of the resonator, Design considerations and data, as well as schematic drawings and test results, are presented, The reported approach provides true fixed-frequency operation under a wide range of sample and environment conditions and over prolonged periods of time, The use of this tunable resonator design in conjunction with an ultra-low-noise fixed-frequency oscillator should enable enhanced sensitivity in EPR measurements of large lossy biological samples. (C) 1995 Academic Press, Inc.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 9 条
[1]   A RADIOFREQUENCY ESR SPECTROMETER FOR INVIVO IMAGING [J].
BRIVATI, JA ;
STEVENS, AD ;
SYMONS, MCR .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (03) :480-489
[2]   AN OPTIMIZED L-BAND CERAMIC RESONATOR FOR EPR IMAGING OF BIOLOGICAL SAMPLES [J].
CHZHAN, M ;
SHTEYNBUK, M ;
KUPPUSAMY, P ;
ZWEIER, JL .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (01) :49-53
[3]  
EATON GR, 1981, EPR IMAGING IN VIVO
[4]   ELECTRON-PARAMAGNETIC-RESONANCE ABSORPTION BY TRIVALENT NEODYMIUM IONS IN SINGLE CRYSTALS OF LANTHANUM TRICHLORIDE AND LANTHANUM ETHYL SULPHATE IN ZERO MAGNETIC FIELD [J].
ERICKSON, LE .
PHYSICAL REVIEW, 1966, 143 (01) :295-&
[5]   PIEZOELECTRIC-CONTROLLED TUNING CAPACITOR FOR SURFACE COILS [J].
HYDE, JS ;
RILLING, RJ ;
JESMANOWICZ, A ;
KNEELAND, JB .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (01) :50-55
[6]   DEVELOPMENT AND OPTIMIZATION OF 3-DIMENSIONAL SPATIAL EPR IMAGING FOR BIOLOGICAL ORGANS AND TISSUES [J].
KUPPUSAMY, P ;
CHZHAN, M ;
ZWEIER, JL .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 106 (02) :122-130
[7]  
POOLE CP, 1967, ELECTRON SPIN RESONA
[8]  
Rogers R. G., 1991, LOW PHASE NOISE MICR
[9]   ELECTRON-PARAMAGNETIC RESONANCE MEASUREMENTS OF FREE-RADICALS IN THE INTACT BEATING HEART - A TECHNIQUE FOR DETECTION AND CHARACTERIZATION OF FREE-RADICALS IN WHOLE BIOLOGICAL TISSUES [J].
ZWEIER, JL ;
KUPPUSAMY, P .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (15) :5703-5707