A THEORETICAL SOLUTION FOR THE FRICTIONLESS ROLLING-CONTACT OF CYLINDRICAL BIPHASIC ARTICULAR-CARTILAGE LAYERS

被引:160
作者
ATESHIAN, GA [1 ]
WANG, HQ [1 ]
机构
[1] COLUMBIA UNIV,DEPT MECH ENGN,ORTHOPAED RES LAB,DEPT ORTHOPAED SURG,NEW YORK,NY 10032
基金
美国国家科学基金会;
关键词
D O I
10.1016/0021-9290(95)00008-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Previous studies have shown that interstitial fluid pressurization plays an important role in the load support mechanism of articular cartilage under normal step loading. These studies have demonstrated that interstitial fluid pressurization decreases with time if the applied load is maintained constant. In the present study, a theoretical solution is obtained for another common loading of articular cartilage, namely the contact of surfaces in rolling motion. Pure rolling of symmetrical frictionless cylindrical cartilage layers is analyzed under steady state. The linear biphasic model of Mow et al. [J. Biomech. Engng 102, 73-84 (1980)] is used to describe the mechanical response of articular cartilage. The solution of this contact problem reduces to simultaneously solving a set of four integral equations, akin to the dual integral problem of elastic contact. It is found that the solution is dependent on four non-dimensional parameters: R(h) = Vb/H(A)k, W/2 mu b, R/b, and v, where V is the surface velocity, b the cartilage thickness, H-A the aggregate modulus, mu the shear modulus, V Poisson's ratio, k the permeability, R the radius of cylindrical surfaces, and W the applied load per unit cylinder length. For R(h) much less than 1, interstitial fluid pressurization is found to be negligible, and all the applied load is supported by the solid collagen-proteoglycan phase of the tissue, thus causing significant cartilage deformation. As R(h) increases to a physiological level(R(h) similar to 10(4)), interstitial fluid pressurization may support more than 90% of the total applied load, shielding the solid matrix from high effective stresses and reducing matrix strains and deformation. The protective effect of interstitial fluid pressurization is observed to increase with increasing joint congruence (R/b); similarly, as the applied load (W/2 mu b) is increased, a greater proportion of it is supported by the fluid. In degenerative cartilage, R(h) may drop by one or more orders of magnitude, primarily as a result of increased permeability. Thus, the protective stress-shielding effect of interstitial fluid pressurization may become less effective in diseased tissue, possibly setting a pathway for further tissue degeneration.
引用
收藏
页码:1341 / 1355
页数:15
相关论文
共 47 条
[1]  
AGBEZUGE LK, 1974, ISRAEL J TECHNOL, V12, P322
[2]   INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .2. RETROPATELLAR SURFACE [J].
AHMED, AM ;
BURKE, DL ;
YU, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :226-234
[3]  
ANDRIACCHI TP, 1991, BASIC ORTHOPAEDIC BI, P51
[4]   An analysis of the stresses in a thin layer of articular cartilage in a synovial joint [J].
Armstrong, C.G. .
Engineering in Medicine, 1986, 15 (02) :55-61
[5]  
ARMSTRONG CG, 1984, J BIOMECH ENG-T ASME, V106, P165, DOI 10.1115/1.3138475
[6]   VARIATIONS IN THE INTRINSIC MECHANICAL PROTERTIES OF HUMAN ARTICULAR-CARTILAGE WITH AGE, DEGENERATION, AND WATER-CONTENT [J].
ARMSTRONG, CG ;
MOW, VC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (01) :88-94
[7]   AN ASYMPTOTIC SOLUTION FOR THE CONTACT OF 2 BIPHASIC CARTILAGE LAYERS [J].
ATESHIAN, GA ;
LAI, WM ;
ZHU, WB ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (11) :1347-1360
[8]  
Ateshian GA, 1992, ADV BIOENG, V22, P191
[9]   INTERSPECIES COMPARISONS OF INSITU INTRINSIC MECHANICAL-PROPERTIES OF DISTAL FEMORAL CARTILAGE [J].
ATHANASIOU, KA ;
ROSENWASSER, MP ;
BUCKWALTER, JA ;
MALININ, TI ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (03) :330-340
[10]  
ATHANASIOU KA, 1991, ASME BIOMECHANICS S, V120, P153