EFFECT OF BATTERY ENERGY-STORAGE SYSTEM ON LOAD FREQUENCY CONTROL CONSIDERING GOVERNOR DEADBAND AND GENERATION RATE CONSTRAINT

被引:105
作者
LU, CF [1 ]
LIU, CC [1 ]
WU, CJ [1 ]
机构
[1] NATL TAIWAN INST TECHNOL,DEPT ELECT ENGN,TAIPEI 10772,TAIWAN
关键词
BATTERY ENERGY STORAGE; MODELING; STABILITY; POWER GENERATION CONTROL;
D O I
10.1109/60.464882
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Since a battery energy storage system (BES) can provide fast active power compensation, it also ran be used to improve the performance of load-frequency control. In this paper a new incremental model of a BES is presented and merged into the load-frequency control of a power system. A comprehensive digital computer model of a two-area interconnected power system including governor deadband and generation rate constraint is employed for a realistic response. Computer simulations show that the BES is very effective in damping the oscillations caused by load disturbances. The BES model is suitable for charging mode and discharging mode operations. Optimization of controller gains is obtained by the second method of Lyapunov.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 17 条
[1]  
DelMonaco J.L., Lewis P.A., Roman H.T., Zemkoski J., Advanced Batteries for Load-Leveling
[2]  
the Utility Perspective on System Integration, Advanced Batteries for Load-Leveling
[3]  
the Utility Perspective on System Integration, 101, 9, pp. 3315-3321, (1982)
[4]  
Lin C.E., Shiao Y.S., Huang C.L., Sung P.S., A Real and Reactive Power Control Approach for Battery Energy Storage System, A Real and Reactive Power Control Approach for Battery Energy Storage System, 7, 3, pp. 1132-1140, (1992)
[5]  
Pivec A., Radimer B.M., Hyman E.A., Utility Operation of Battery Energy Storage at the BEST Facility, Utility Operation of Battery Energy Storage at the BEST Facility, 1, 3, pp. 47-54, (1986)
[6]  
Kunisch H.J., Kramer K.G., Dominik H., Battery Energy Storage, Another Option for Load-Frequency-Control and Instantaneous Reserve, Battery Energy Storage, Another Option for Load-Frequency-Control and Instantaneous Reserve, 1, 3, pp. 41-46, (1986)
[7]  
Walker L.H., 10 MW GTO Converter for Battery Peaking Service, 10 MW GTO Converter for Battery Peaking Service, 26, 1, pp. 63-72, (1990)
[8]  
Banetjee S., Chatteijee J.K., Tripathy S.C., Application of Magnetic Energy Storage Unit as Load-Frequency Stabilizer, Application of Magnetic Energy Storage Unit as Load-Frequency Stabilizer, 5, 1, pp. 46-51, (1990)
[9]  
Elgerd O.I., Electric Energy Systems Theory - An Introduction, (1982)
[10]  
Salameh Z.M., Casacca M.A., Lynch W.A., A Mathematical Model for Lead-Acid Batteries, A Mathematical Model for Lead-Acid Batteries, 7, 1, pp. 93-97, (1992)