MECHANICAL-PROPERTIES OF THE FIBROUS TISSUE FOUND AT THE BONE-CEMENT INTERFACE FOLLOWING TOTAL JOINT REPLACEMENT

被引:119
作者
HORI, RY
LEWIS, JL
机构
[1] Rehabil. Eng. Program, Northwest. Univ., Chicago, IL 60611, United States
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1982年 / 16卷 / 06期
关键词
BIOLOGICAL MATERIALS - Tissue - BIOMEDICAL ENGINEERING - Surgical Implants - MATERIALS TESTING - Medical Applications - POLYETHYLENES - Medical Applications - POLYMETHYL METHACRYLATE - Medical Applications;
D O I
10.1002/jbm.820160615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Harvestable amounts of interfacial fibrous tissue were generated using a prosthetic replacement of the canine stifle joint as an animal model. The collected tissues were examined histologically and by uniaxial, unconfined compression tests. The fibrous tissue had a matlike structure. The heavy collagen fibers were distributed at random in sheets and the sheets themselves were layered to form a mat. Such a structure may be able to resist compressive stresses normal to the plane of the mat but is probably not well suited to resist shearing stresses. The fibrous tissue proved to be a very compliant, deformable material and to undergo very large strains with load. The stress-strain curve for the tissue was nonlinear and was characterized by large deformations at low loads. But with increasing loads, the material became stiffer, and at high loads, the stress-strain curve became linear. With regard to total joint replacement systems which consist of an outer bone shell followed by a thin layer of fibrous tissue, a mantle of PMMA cement and a central core of metal or UHMW polyethylene, the fibrous tissue is substantially more yielding and deformable than the other elements of the structure and may have a significant effect on the structural behavior of the system.
引用
收藏
页码:911 / 927
页数:17
相关论文
共 11 条
[1]  
BLACKER G, 1978, CLIN ORTHOP RELAT R, V137, P15
[2]  
Charnley J., 1974, LOW FRICTION ARTHROP
[3]  
DIETSCHI C, 1976, TOTAL HIP PROSTHESIS, P144
[4]  
DUCHEYNE P, 1978, J BIOMECH, V11, P297, DOI 10.1016/0021-9290(78)90063-5
[5]   INDENTATION TESTS OF HUMAN ARTICULAR-CARTILAGE [J].
HORI, RY ;
MOCKROS, LF .
JOURNAL OF BIOMECHANICS, 1976, 9 (04) :259-268
[6]  
INSALL J, 1979, J BONE JOINT SURG A, V61, P174
[7]   THE EFFECT OF CALCAR CONTACT ON FEMORAL COMPONENT MICROMOVEMENT - A MECHANICAL STUDY [J].
MARKOLF, KL ;
AMSTUTZ, HC ;
HIRSCHOWITZ, DL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (08) :1315-1323
[8]  
MILLER JE, 1979, 25TH ANN M ORTH RES
[9]   BIPHASIC CREEP AND STRESS-RELAXATION OF ARTICULAR-CARTILAGE IN COMPRESSION - THEORY AND EXPERIMENTS [J].
MOW, VC ;
KUEI, SC ;
LAI, WM ;
ARMSTRONG, CG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01) :73-84
[10]   LOAD ACTIONS ON HUMAN FEMUR IN WALKING AND SOME RESULTANT STRESSES [J].
PAUL, JP .
EXPERIMENTAL MECHANICS, 1971, 11 (03) :121-&