AUTOMATED MICROANALYSIS OF CARBAMAZEPINE AND ITS EPOXIDE AND TRANS-DIOL METABOLITES IN PLASMA BY COLUMN LIQUID-CHROMATOGRAPHY

被引:23
作者
ROUAN, MC
CAMPESTRINI, J
LECLANCHE, V
LECAILLON, JB
GODBILLON, J
机构
[1] Laboratoires CIBA-GEIGY, Biopharmaceutical Research Center, 92506 Rueil-Malmaison Cedex
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 573卷 / 01期
关键词
D O I
10.1016/0378-4347(92)80475-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated high-performance liquid chromatographic procedure for the simultaneous determination of carbamazepine and its main metabolites, epoxycarbamazepine and dihydroxycarbamazepine, in plasma is described. Liquid-solid extraction on disposable C18 columns and reversed-phase chromatography on a 3-mu-m particle size C18 column were combined and automated by using the Automatic Sample Preparation with Extraction Columns system. Ultraviolet detection was performed at 210 nm. 5,6-Dihydro-11-oxo-11H-dibenz[b,e]azepine-5-carboxamide was used as internal standard. A small plasma volume (100-mu-l) was required. The total run time for the assay of one sample was about 10 min. The assay demonstrated good reproducibility. The limit of quantitation was 0.1-mu-mol/l (about 25 ng/ml).
引用
收藏
页码:65 / 68
页数:4
相关论文
共 7 条
[1]   SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CARBAMAZEPINE AND ITS PRINCIPAL METABOLITES IN HUMAN-PLASMA AND URINE [J].
CHELBERG, RD ;
GUNAWAN, S ;
TREIMAN, DM .
THERAPEUTIC DRUG MONITORING, 1988, 10 (02) :188-193
[2]   SIMULTANEOUS DETERMINATION OF CARBAMAZEPINE, OXCARBAZEPINE AND THEIR MAIN METABOLITES IN PLASMA BY LIQUID-CHROMATOGRAPHY [J].
MENGE, GP ;
DUBOIS, JP ;
BAUER, G .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (02) :477-483
[3]  
RIAD LE, 1988, CLIN CHEM, V34, P1863
[4]   FAST LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF DRUGS IN PLASMA AND COMBINATION WITH LIQUID SOLID EXTRACTION IN A FULLY AUTOMATED-SYSTEM [J].
ROUAN, MC ;
LEDUIGOU, F ;
CAMPESTRINI, J ;
LECAILLON, JB ;
GODBILLON, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01) :59-64
[5]   FULLY AUTOMATED ANALYTICAL SYSTEM USING LIQUID-SOLID EXTRACTION AND LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF CGP-6140 IN PLASMA [J].
ROUAN, MC ;
CAMPESTRINI, J ;
LECAILLON, JB ;
DUBOIS, JP ;
LAMONTAGNE, M ;
PICHON, B .
JOURNAL OF CHROMATOGRAPHY, 1988, 456 (01) :45-51
[6]   REVIEW OF STATISTICAL CONSIDERATIONS INVOLVED IN TREATMENT OF ISOTOPE DILUTION CALIBRATION DATA [J].
SCHOELLER, DA .
BIOMEDICAL MASS SPECTROMETRY, 1976, 3 (06) :265-271
[7]  
VERILLON F, 1987, INT LAB JUL, P50