AN ACOUSTIC SCREENING-TEST FOR OBSTRUCTIVE SLEEP-APNEA

被引:23
作者
MCCOMBE, AW [1 ]
KWOK, V [1 ]
HAWKE, WM [1 ]
机构
[1] UNIV TORONTO,DEPT OTOLARYNGOL,TORONTO,ON M5S 1A1,CANADA
来源
CLINICAL OTOLARYNGOLOGY | 1995年 / 20卷 / 04期
关键词
ACOUSTIC; SCREENING; OBSTRUCTIVE SLEEP APNEA;
D O I
10.1111/j.1365-2273.1995.tb00057.x
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Third-octave sound analysis was performed on the snoring sounds of nine subjects with obstructive sleep apnoea (OSA) and 18 with simple snoring. Both groups demonstrated a large low frequency peak in linear sound levels at around 80 Hz. However, the OSA. group displayed a substantially larger high frequency sound component. We utilized this fact in the development of an acoustic index (Hawke Index: HI) which describes the ratio between the overall A-weighted and linear sound levels for the recorded snoring sound of each subject [HI = dB(A)/dB(SPL) for Lmax]. There was a significant positive correlation between the apnoea/hypopnoea index and the HI (r = 0.73, t = 5.3, 25df, P < 0.001). If a value of 0.90 or greater was taken as diagnostic of OSA, the HI exhibited 67% sensitivity, 100% specificity, 100% positive and 86% negative predictive accuracy. With further development, we believe this acoustic phenomena may have a role as a screening test in the diagnosis of OSA.
引用
收藏
页码:348 / 351
页数:4
相关论文
共 14 条
[1]   ABC OF SLEEP DISORDERS - THE SLEEP-APNEA HYPOPNEA SYNDROME AND SNORING [J].
DOUGLAS, NJ .
BRITISH MEDICAL JOURNAL, 1993, 306 (6884) :1057-1060
[2]   MORTALITY AND APNEA INDEX IN OBSTRUCTIVE SLEEP-APNEA - EXPERIENCE IN 385 MALE-PATIENTS [J].
HE, J ;
KRYGER, MH ;
ZORICK, FJ ;
CONWAY, W ;
ROTH, T .
CHEST, 1988, 94 (01) :9-14
[3]   SNORING - IS IT IN THE EAR OF THE BEHOLDER [J].
HOFFSTEIN, V ;
MATEIKA, S ;
ANDERSON, D .
SLEEP, 1994, 17 (06) :522-526
[4]  
HOFFSTEIN V, 1993, SLEEP, V16, P118
[5]   DIGITAL MONITORING OF SLEEP-DISORDERED BREATHING USING SNORING SOUND AND ARTERIAL OXYGEN-SATURATION [J].
ISSA, FG ;
MORRISON, D ;
HADJUK, E ;
IYER, A ;
FEROAH, T ;
REMMERS, JE .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (04) :1023-1029
[6]   THE PREDICTIVE ACCURACY OF HOME OXIMETRY IN PATIENTS WITH SUSPECTED OBSTRUCTIVE SLEEP-APNEA [J].
KEENAN, SP ;
ANDERSON, B ;
WIGGS, B ;
RYAN, CF ;
FLEETHAM, JA .
SLEEP, 1993, 16 (08) :S133-S134
[7]  
MESLIER N, 1990, American Review of Respiratory Disease, V141, pA857
[8]   ONE NEGATIVE POLYSOMNOGRAM DOES NOT EXCLUDE OBSTRUCTIVE SLEEP-APNEA [J].
MEYER, TJ ;
EVELOFF, SE ;
KLINE, LR ;
MILLMAN, RP .
CHEST, 1993, 103 (03) :756-760
[9]   CHARACTERISTICS OF THE SNORING NOISE IN PATIENTS WITH AND WITHOUT OCCLUSIVE SLEEP-APNEA [J].
PEREZPADILLA, JR ;
SLAWINSKI, E ;
DIFRANCESCO, LM ;
FEIGE, RR ;
REMMERS, JE ;
WHITELAW, WA .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (03) :635-644
[10]   SNORING AND PRESBYACUSIS [J].
PRAZIC, M .