FRACTAL ANALYSIS OF ELECTROENCEPHALOGRAPHIC SIGNALS INTRACEREBRALLY RECORDED DURING 35 EPILEPTIC SEIZURES - EVALUATION OF A NEW METHOD FOR SYNOPTIC VISUALIZATION OF ICTAL EVENTS

被引:50
作者
BULLMORE, ET
BRAMMER, MJ
BOURLON, P
ALARCON, G
POLKEY, CE
ELWES, R
BINNIE, CD
机构
[1] INST PSYCHIAT,DEPT BIOSTAT & COMP,LONDON SE5 8AF,ENGLAND
[2] MAUDSLEY HOSP & INST PSYCHIAT,DEPT CLIN NEUROPHYSIOL,LONDON,ENGLAND
[3] MAUDSLEY HOSP & INST PSYCHIAT,DEPT NEUROSURG,LONDON,ENGLAND
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1994年 / 91卷 / 05期
基金
英国惠康基金;
关键词
FRACTAL ANALYSIS; EPILEPSY; VISUALIZATION; STEREOELECTROENCEPHALOGRAPHY (SEEG); ELECTROENCEPHALOGRAPHY;
D O I
10.1016/0013-4694(94)00181-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Traditional electroencephalography (EEG) produces a large volume display of brain electrical activity, which creates problems particularly in assessment of long periods of intracranial, stereoelectroencephalographic (SEEG) recording. A method for fractal analysis that describes 100 SEEG data points in terms of a single estimate of fractal dimension (1 < FD < 2) is reported; the central processing unit time costs amount to approximately 2 min/Mbyte of input signal (using a Sun SPARCstation LX). The diagnostic sensitivity of this method, applied to quantification and synoptic visualisation of SEEG signals recorded during 35 epileptic seizures in 7 patients, is evaluated. II is found that the method consistently defines ictal onset in terms of rapid relative increase in FD across several channels. Clinically severe seizures are characterised by more intense and generalised ictal changes in FD than clinically less severe events. For all 7 patients, and for 75% of individual seizures, ''fractal diagnoses'' of anatomically defined ictal onset zone coincided closely with ictal onset zone independently determined by inspection of traditional EEG displays of the same data. We conclude that the method is a computationally feasible way to achieve substantial reduction in the volume of SEEG data without undue loss of diagnostically important information in the primary signal.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 28 条
[1]  
Albano AM, 1987, CHAOS BIOLOG SYST, P207, DOI 10.1007/978-1-4757-9631-5_24
[2]  
[Anonymous], 1991, FRACTALS CHAOS POWER
[3]   AN APPLICATION OF FRACTAL DIMENSION TO THE DETECTION OF TRANSIENTS IN THE ELECTROENCEPHALOGRAM [J].
ARLE, JE ;
SIMON, RH .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 75 (04) :296-305
[4]   FRACTAL FUNCTIONS AND INTERPOLATION [J].
BARNSLEY, MF .
CONSTRUCTIVE APPROXIMATION, 1986, 2 (04) :303-329
[5]  
BINNIE CD, 1983, RECENT ADV EPILEPSY, V1, P155
[6]   FRACTAL ELECTROENCEPHALOGRAPHY [J].
BULLIMORE, E ;
BRAMMER, M ;
BINNIE, C ;
ALARCON, G .
LANCET, 1992, 339 (8793) :618-619
[7]   A NEW TECHNIQUE FOR FRACTAL ANALYSIS APPLIED TO HUMAN, INTRACEREBRALLY RECORDED, ICTAL ELECTROENCEPHALOGRAPHIC SIGNALS [J].
BULLMORE, E ;
BRAMMER, M ;
ALARCON, G ;
BINNIE, C .
NEUROSCIENCE LETTERS, 1992, 146 (02) :227-230
[8]  
BULLMORE ET, 1994, FRACTALS NATURAL APP, P69
[9]   A COMPARATIVE-STUDY OF THE EXPERIMENTAL QUANTIFICATION OF DETERMINISTIC CHAOS [J].
DESTEXHE, A ;
SEPULCHRE, JA ;
BABLOYANTZ, A .
PHYSICS LETTERS A, 1988, 132 (2-3) :101-106
[10]   ON SOME PROBLEMS ENCOUNTERED IN THE ESTIMATION OF THE CORRELATION DIMENSION OF THE EEG [J].
DVORAK, I ;
SISKA, J .
PHYSICS LETTERS A, 1986, 118 (02) :63-66