THE QUANTIFICATION OF EMG NORMALIZATION ERROR

被引:155
作者
MIRKA, GA
机构
[1] Department of Industrial and Systems Engineering, The Ohio State University, Columbus, OH
关键词
BIOMECHANICS; ELECTROMYOGRAPHY; EMG; NORMALIZATION;
D O I
10.1080/00140139108967318
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electromyography (EMG) and normalized EMG have been accepted as methods of quantifying the activity level of a muscle. Normalized EMG, in conjunction with the EMG/force relationship and muscle cross-sectional area data, allows researchers to estimate the amount of muscle force exerted across a joint. An accurate description of this muscle force is a critical input to models designed to described the risk of injury of a task. In order to be able to make statements about the relative intensity of an EMG signal, researchers who use normalization procedures take a given EMG activity level, at a known joint angle, and relate it to some reference activity level obtained at that particular joint angle. However, there have been studies where the EMG activity of an unrestricted dynamic task, such as walking, cycling, performing an occupational task, etc., has been normalized with respect to an EMG value taken during a single maximum voluntary contraction performed at one reference joint angle. This practice will render inaccurate results because at different joint angles there are changes in the portion of the muscle within the viewing area of the electrode, as well as changes in the maximum EMG value. The present study was an attempt to quantify the errors associated with normalization relative to a reference EMG value collected at an arbitrary joint position. Four subjects performed these exertions the EMG activities were collected for eight trunk muscles. The task EMG values that resulted were then: (1) all normalized with respect to the maximum EMG at a single arbitrary trunk angle and (2) each normalized with respect to that specific trunk angle's maximum EMG. The results show that for the primary trunk extensors (erector spinae) large errors (> 75%) resulted from normalization using a single reference point and the magnitude of these errors followed consistent patterns within subjects as a function of trunk angle.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 7 条
[1]  
DUBO HIC, 1976, ARCH PHYS MED REHAB, V57, P415
[2]  
ERICSON MO, 1986, SCAND J REHABIL MED, V18, P159
[3]  
ERICSON MO, 1985, SCAND J REHABIL MED, V17, P53
[4]   TIMING AND RELATIVE INTENSITY OF HIP EXTENSOR AND ABDUCTOR MUSCLE ACTION DURING LEVEL AND STAIR AMBULATION - AN EMG STUDY [J].
LYONS, K ;
PERRY, J ;
GRONLEY, JK ;
BARNES, L ;
ANTONELLI, D .
PHYSICAL THERAPY, 1983, 63 (10) :1597-1605
[5]   THE RELATIONSHIP BETWEEN TRUNK MUSCLE ELECTROMYOGRAPHY AND LIFTING MOMENTS IN THE SAGITTAL AND FRONTAL PLANES [J].
SEROUSSI, RE ;
POPE, MH .
JOURNAL OF BIOMECHANICS, 1987, 20 (02) :135-&
[6]  
SODERBERG G, IN PRESS MANUAL SURF
[7]  
YANG J, 1984, ARCH PHYSICAL MED RE, V16, P517