PSEUDOBACTERAEMIA WITH MULTIPLY-RESISTANT KLEBSIELLA-PNEUMONIAE RESULTING FROM CONTAMINATION FROM THE BLOOD-GAS MACHINE ON A NEONATAL UNIT

被引:6
作者
JUMAA, P
CHATTOPADHYAY, B
机构
[1] WHIPPS CROSS HOSP & CHEST CLIN,DEPT MICROBIOL,LONDON E11 1NR,ENGLAND
[2] WHIPPS CROSS HOSP & CHEST CLIN,PUBL HLTH LAB,LONDON EH11 1NR,ENGLAND
关键词
PSEUDOBACTERAEMIA; KLEBSIELLA-PNEUMONIAE; GENTAMICIN RESISTANCE; BLOOD GAS MACHINE;
D O I
10.1016/0195-6701(92)90049-R
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Klebsiella pneumoniae with an unusual antibiotic susceptibility pattern was isolated from blood cultures of seven unwell premature babies on the Special Care Baby Unit. Although the organism was sensitive to cefuroxime it was resistant to ceftazidime. It was also resistant to gentamicin, tobramycin, netilmicin, piperacillin and aztreonam but sensitive to ciprofloxacin, imipenem and amikacin. On extensive investigation to trace the source, a K. pneumoniae with the same susceptibility pattern as that obtained from blood cultures was isolated from the probe and probe cover on the blood gas machine but not from any other environmental samples or clinical specimens. Where clinically indicated, antibiotics were used to treat these babies, with success. The difficulty, however, of differentiating between true septicaemia and pseudobacteraemia could be enormous as withholding treatment will have disastrous consequences in genuine cases of bacteraemia. © 1992.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 8 条
[1]  
COOKSON BD, 1982, LANCET, V2, P1276
[2]   AN UNEXPECTED CAUSE OF PSEUDOBACTEREMIA [J].
COX, RA .
JOURNAL OF HOSPITAL INFECTION, 1989, 14 (03) :266-266
[3]   PSEUDOBACTEREMIA AGAIN [J].
MCLAUCHLAN, DM ;
ROGERS, CE ;
WHALE, K .
JOURNAL OF HOSPITAL INFECTION, 1988, 12 (02) :133-134
[4]   MECHANISM OF CROSS-CONTAMINATION OF BLOOD CULTURE BOTTLES IN OUTBREAKS OF PSEUDOBACTEREMIA ASSOCIATED WITH NONSTERILE BLOOD COLLECTION TUBES [J].
MCNEIL, MM ;
DAVIS, BJ ;
ANDERSON, RL ;
MARTONE, WJ ;
SOLOMON, SL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (01) :23-25
[5]  
Pitt T L, 1982, J Hosp Infect, V3, P395, DOI 10.1016/0195-6701(82)90074-3
[6]  
WHALE K, 1983, LANCET, V1, P830
[7]   PSEUDOMONAS-CEPACIA PSEUDOBACTEREMIA ASSOCIATED WITH A CONTAMINATED BLOOD-GAS ANALYZER [J].
WILSON, JA ;
VIGGARS, S ;
PARSONS, A .
JOURNAL OF HOSPITAL INFECTION, 1987, 10 (03) :314-315
[8]  
WILSON PA, 1981, BRIT MED J, V283, P866