OPEN CHANNEL NOISE .6. ANALYSIS OF AMPLITUDE HISTOGRAMS TO DETERMINE RAPID KINETIC-PARAMETERS

被引:48
作者
HEINEMANN, SH [1 ]
SIGWORTH, FJ [1 ]
机构
[1] YALE UNIV,SCH MED,DEPT CELLULAR & MOLEC PHYSIOL,NEW HAVEN,CT 06510
关键词
D O I
10.1016/S0006-3495(91)82087-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Recently we reported that rapid fluctuations of ion currents flowing through open gramicidin A channels exceed the expected level of pure transport noise at low ion concentrations (Heinemann, S. H. and F. J. Sigworth. 1990. Biophys. J 57:499-514). Based on comparisons with kinetic ion transport models we concluded that this excess noise is likely caused by current interruptions lasting approximately 1-mu-s. Here we introduce a method using the higher-order cumulants of the amplitude distribution to estimate the kinetics of channel closing events far below the actual time resolution of the recording system. Using this method on data recorded with 10 kHz bandwidth, estimates for gap time constants on the order of 1-mu-s were obtained, similar to the earlier predictions.
引用
收藏
页码:577 / 587
页数:11
相关论文
共 24 条