STORAGE PHOSPHOR VERSUS SCREEN-FILM RADIOGRAPHY - EFFECT OF VARYING EXPOSURE PARAMETERS AND UNSHARP MASK FILTERING ON THE DETECTABILITY OF CORTICAL BONE DEFECTS

被引:42
作者
PROKOP, M
GALANSKI, M
OESTMANN, JW
VONFALKENHAUSEN, U
ROSENTHAL, H
REIMER, P
NISCHELSKY, J
REICHELT, S
机构
[1] Department of Diagnostic Radiology I, Medizinische Hochschule Hannover, D-3000 Hannover 61
关键词
Bones; radiography; 40.11; 40.1215; Radiography; comparative studies; digital; storage phosphor; technology; Screens and films;
D O I
10.1148/radiology.177.1.2399307
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diagnostic performance with storage phosphor radiography is influenced by exposure parameters and digital filtering algorithms. The authors compared the detectability of cortical lesions in excised human femoral shafts on state-of-the-art screen-film radiographs and storage phosphor digital radiographs. For the digital system, the effect of varying exposure parameters (photon flux and tube voltage) and unsharp mask filtering (kernel size and enhancement factor) was tested. Analysis of receiver operating characteristics was performed for 10,560 observations made by eight radiologists. Under identical exposure conditions, storage phosphor imaging yielded no significant advantages over conventional screen-film radiography. Although large variations in exposure dose are possible with storage phosphors, the potential for dose reduction was limited even by means of an increase in tube voltage. The performance with unsharp masked images declined with decreasing kernel size and pronounced enhancement.
引用
收藏
页码:109 / 113
页数:5
相关论文
共 11 条
[1]   MEASURING OBSERVER PERFORMANCE BY ROC ANALYSIS - INDICATIONS AND COMPLICATIONS [J].
BERBAUM, KS ;
DORFMAN, DD ;
FRANKEN, EA .
INVESTIGATIVE RADIOLOGY, 1989, 24 (03) :228-233
[2]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[3]  
HILL AB, 1971, PRINCIPLES MED STATI, P143
[4]  
Ishida M., 1983, RADIOGRAPHICS, V3, P325
[5]   INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .4. EFFECT OF UNSHARP MASKING ON THE DETECTABILITY OF SIMPLE PATTERNS [J].
LOO, LND ;
DOI, K ;
METZ, CE .
MEDICAL PHYSICS, 1985, 12 (02) :209-214
[6]   BASIC PRINCIPLES OF ROC ANALYSIS [J].
METZ, CE .
SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) :283-298
[8]  
MURPHEY MD, 1990, RADIOLOGY, V74, P865
[9]   HIGH-FREQUENCY EDGE ENHANCEMENT IN THE DETECTION OF FINE PULMONARY LINES - PARITY BETWEEN STORAGE PHOSPHOR DIGITAL IMAGES AND CONVENTIONAL CHEST RADIOGRAPHY [J].
OESTMANN, JW ;
GREENE, R ;
RUBENS, JR ;
PILESPELLMAN, E ;
HALL, D ;
ROBERTSON, C ;
LLEWELLYN, HJ ;
MCCARTHY, KA ;
POTSAID, M ;
WHITE, G .
INVESTIGATIVE RADIOLOGY, 1989, 24 (09) :643-646
[10]  
PETTERSSON H, 1988, ACTA RADIOL, V29, P267