MECHANICAL STRENGTH OF REPAIRS OF THE ROTATOR CUFF

被引:501
作者
GERBER, C
SCHNEEBERGER, AG
BECK, M
SCHLEGEL, U
机构
[1] UNIV BERN,DEPT ORTHOPAED,BERN,SWITZERLAND
[2] AO RES INST,CH-7270 DAVOS,SWITZERLAND
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1994年 / 76B卷 / 03期
关键词
D O I
10.1302/0301-620X.76B3.8175836
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Alien suture technique improved the ultimate tensile strength to 359 N for two stitches.
引用
收藏
页码:371 / 380
页数:10
相关论文
共 30 条
[1]  
BOURNE RB, 1988, CAN J SURG, V31, P43
[2]   ANTERIOR AND POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION IN RHESUS-MONKEYS - A HISTOLOGICAL, MICRO-ANGIOGRAPHIC, AND BIOMECHANICAL ANALYSIS [J].
CLANCY, WG ;
NARECHANIA, RG ;
ROSENBERG, TD ;
GMEINER, JG ;
WISNEFSKE, DD ;
LANGE, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (08) :1270-1284
[3]  
COWAN R J, 1959, Can J Surg, V2, P373
[4]  
CRAIG PH, 1975, SURG GYNECOL OBSTET, V141, P1
[5]   TENDON SUTURE TO BONE - AN EXPERIMENTAL INVESTIGATION IN RABBITS [J].
FORWARD, AD ;
COWAN, RJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1963, 45 (04) :807-823
[6]   BIOMECHANICAL EVALUATION OF ROTATOR CUFF FIXATION METHODS [J].
FRANCE, EP ;
PAULOS, LE ;
HARNER, CD ;
STRAIGHT, CB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (02) :176-181
[7]  
GOUTALLIER D, 1989, REV CHIR ORTHOP S1, V75, P126
[8]   REPAIRS OF THE ROTATOR CUFF - CORRELATION OF FUNCTIONAL RESULTS WITH INTEGRITY OF THE CUFF [J].
HARRYMAN, DT ;
MACK, LA ;
WANG, KY ;
JACKINS, SE ;
RICHARDSON, ML ;
MATSEN, FA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (07) :982-989
[9]  
HERRMANN JB, 1970, ARCH SURG-CHICAGO, V100, P486
[10]  
Kessler I, 1973, Hand, V5, P253, DOI 10.1016/0072-968X(73)90038-7