INTRAOSSEOUS CELLULAR-RESPONSE TO BIODEGRADABLE FRACTURE FIXATION SCREWS MADE OF POLYGLYCOLIDE OR POLYLACTIDE

被引:104
作者
PAIVARINTA, U
BOSTMAN, O
MAJOLA, A
TOIVONEN, T
TORMALA, P
ROKKANEN, P
机构
[1] UNIV HELSINKI,CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,SF-00260 HELSINKI,FINLAND
[2] UNIV TECHNOL TAMPERE,BIOMAT LAB,SF-33710 TAMPERE,FINLAND
关键词
D O I
10.1007/BF00420258
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
As biodegradable pins and screws have increasingly been used in the internal fixation of fractures, sterile inflammatory reactions have occasionally occurred. The aim of the present experimental study was to assess the cellular response within cancellous bone to biodegradable polyester screws. In 45 rabbis a transverse distal femoral osteotomy was fixed with a 4.5 x 30 mm screw made either of polyglycolide (PGA, in 20 rabbits) or polylactide (PLA, in 25 rabbits). The follow-up times were 3, 6, 12, 36 or 48 weeks. The time-related and spatial characteristics of the cellular response were examined histomorphometrically using standardised sample fields under polarised-light microscopy. Polymorphonuclear granulocytes and mononuclear round cells were scarce in all follow-up groups. The occurrence of phagocytic cells (mononuclear macrophages and foreign-body giant cells) was highest in the PGA-fixed 12-week specimens. The giant cells seemed to adhere to the implant surface at an early stage, whereas the ultimate digestion and clearing of the decomposing polymeric material later on were performed by macrophages invading the implant body. No PGA was left in the 36-week specimens, while the gross geometry of the PLA screws was still intact at 48 weeks. In conclusion, the inflammatory response to these polymers was quite mild. Thus it seems probable that some other additional factors must influence the occurrence of the clinical inflammatory reactions.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 20 条
[1]   DEGRADATION OF AND TISSUE REACTION TO BIODEGRADABLE POLY(L-LACTIDE) FOR USE AS INTERNAL-FIXATION OF FRACTURES - A STUDY IN RATS [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
VERWEY, AB ;
NIEUWENHUIS, P ;
JANSEN, HWB .
BIOMATERIALS, 1991, 12 (01) :32-36
[2]   BIODEGRADABLE INTERNAL-FIXATION FOR MALLEOLAR FRACTURES - A PROSPECTIVE RANDOMIZED TRIAL [J].
BOSTMAN, O ;
VAINIONPAA, S ;
HIRVENSALO, E ;
MAKELA, A ;
VIHTONEN, K ;
TORMALA, P ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :615-619
[3]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[4]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[5]  
DELBEKE LO, 1983, FERTIL STERIL, V40, P248
[6]  
EITENMULLER J, 1990, 92ND FRENCH SURG C P
[7]   SEVERE ASEPTIC SYNOVITIS OF THE KNEE AFTER BIODEGRADABLE INTERNAL-FIXATION - A CASE-REPORT [J].
FRIDEN, T ;
RYDHOLM, U .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :94-97
[8]  
GAMMELGAARD N, 1983, ACTA CHIR SCAND, V149, P505
[9]  
HOFFMANN R, 1989, UNFALLCHIRURG, V92, P430
[10]  
MAJOLA A, 1991, ANN CHIR GYNAECOL FE, V80, P274