INHOMOGENEITY CORRECTION FOR INVIVO SPECTROSCOPY BY HIGH-RESOLUTION WATER REFERENCING

被引:39
作者
WEBB, P
SPIELMAN, D
MACOVSKI, A
机构
[1] Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, 94305
关键词
D O I
10.1002/mrm.1910230102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the most common sources of distortion in in vivo spectroscopy is the inhomogeneity of the main magnetic field. This effect is particularly problematic when performing spectroscopic imaging, as the shim cannot be simultaneously optimized for all voxels. In this paper we present a technique to measure inhomogeneity rapidly, then show how to use the measurement to improve the analysis of the spectrum. This technique can be applied in conjunction with any spectroscopic localization method and any spectral quantitation algorithm. We present results from spectroscopic imaging of phantoms, then show application to a single‐voxel water‐suppressed proton brain study. We find that the quantitation of the in vivo spectrum is made immune to inhomogeneous line broadening. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:1 / 11
页数:11
相关论文
共 16 条
  • [1] NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS
    BROWN, TR
    KINCAID, BM
    UGURBIL, K
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11): : 3523 - 3526
  • [2] BURG J, 1972, GEOPHYSICS, V137, P375
  • [3] RESOLUTION ENHANCEMENT BY NONLINEAR DATA-PROCESSING - HOGWASH AND THE MAXIMUM-ENTROPY METHOD
    DAVIES, SJ
    BAUER, C
    HORE, PJ
    FREEMAN, R
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 76 (03) : 476 - 493
  • [4] QUALITY - QUANTIFICATION IMPROVEMENT BY CONVERTING LINESHAPES TO THE LORENTZIAN TYPE
    DEGRAAF, AA
    VANDIJK, JE
    BOVEE, WMMJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (03) : 343 - 357
  • [5] DEGRAAF AA, 1989, 8TH P ANN M SOC MAGN, P224
  • [6] SIMPLE PROTON SPECTROSCOPIC IMAGING
    DIXON, WT
    [J]. RADIOLOGY, 1984, 153 (01) : 189 - 194
  • [7] LOCALIZED HIGH-RESOLUTION PROTON NMR-SPECTROSCOPY USING STIMULATED ECHOES - INITIAL APPLICATIONS TO HUMAN-BRAIN INVIVO
    FRAHM, J
    BRUHN, H
    GYNGELL, ML
    MERBOLDT, KD
    HANICKE, W
    SAUTER, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) : 79 - 93
  • [8] LISICKI M, 1988, 29TH P EXPT NUCL MAG, P183
  • [9] MEYER C, 1988, 7TH P SOC MAGN RES M, P653
  • [10] SIMULTANEOUS SPATIAL AND SPECTRAL SELECTIVE EXCITATION
    MEYER, CH
    PAULY, JM
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (02) : 287 - 304