SELF-SUPPORTING CYLINDRICAL MULTIWIRE PROPORTIONAL CHAMBERS WITH TWO-DIMENSIONAL READ-OUT

被引:5
作者
KOBAYASHI, M
KUROKAWA, SI
FUJITANI, T
NAGASHIMA, Y
OMORI, T
SUGIMOTO, S
YAMAGUCHI, Y
IWAHORI, JI
YOSHIDA, H
TAKEUTCHI, F
机构
[1] KYOTO SANGYO UNIV,KITA KU,KYOTO 603,JAPAN
[2] OSAKA UNIV,DEPT PHYS,TOYONAKA,OSAKA 560,JAPAN
[3] FUKUOKA DENT COLL,FAC ENGN,FUKUOKA 814,JAPAN
关键词
NUCLEAR INSTRUMENTATION - Readout Systems - PHYSICS - High Energy;
D O I
10.1016/0168-9002(86)90257-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cylindrical MWPCs have been constructed with anode diameters of 240-430 mm and a length of 750 mm. Cathode strips run helically with 38 degree -61 degree to the anode wires, and the induced charges were read out by ADC. Both the anode and the cathode efficiency were well above 99%. The resolution ( sigma ) for the longitudinal position of the avalanche was 0. 6 mm by the center of gravity method, if the cathode was read out per 12 mm width by summing two adjacent cathode strips.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 10 条
  • [1] AIKEN G, 1980, SLACPUB2642
  • [2] AMAKO K, 1976, KEK EXP FACILITIES 3
  • [3] STUDY OF POSITION RESOLUTION FOR CATHODE READOUT MWPC WITH MEASUREMENT OF INDUCED CHARGE-DISTRIBUTION
    CHIBA, J
    IWASAKI, H
    KAGEYAMA, T
    KURIBAYASHI, S
    NAKAMURA, K
    SUMIYOSHI, T
    TAKEDA, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 451 - 463
  • [4] Chiba M., 1985, Proceedings of the Meeting on Few-Body Problems in High and Medium Energy Physics (KEK 85-13), P40
  • [5] CHIBA M, UNPUB
  • [6] SYSTEMATIC SHIFTS OF EVALUATED CHARGE CENTROID FOR THE CATHODE READOUT MULTIWIRE PROPORTIONAL CHAMBER
    ENDO, I
    KAWAMOTO, T
    MIZUNO, Y
    OHSUGI, T
    TANIGUCHI, T
    TAKESHITA, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 188 (01): : 51 - 58
  • [7] HIGH-VOLTAGE READ-OUT FOR MULTIWIRE PROPORTIONAL CHAMBERS
    FISCHER, G
    PLCH, J
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1972, 100 (03): : 515 - &
  • [8] INABA S, COMMUNICATION
  • [9] KOBAYASHI M, 1984, KEK8410 REP
  • [10] BIFILAR HELICAL MULTIWIRE PROPORTIONAL CHAMBER FOR POSITION SENSITIVE DETECTION OF MINIMUM IONIZING PARTICLES
    LEE, DM
    THIESSEN, HA
    SOBOTTKA, SE
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (01): : 179 - &