EVALUATION OF ALKYL BONDED SILICA AND SOLVENT PHASE MODIFIERS FOR THE EFFICIENT ELUTION OF BASIC DRUGS ON HPLC

被引:29
作者
HILL, DW
机构
[1] Microchemistry Laboratory, University of Connecticut, Storrs
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1990年 / 13卷 / 16期
关键词
D O I
10.1080/01483919008049094
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nine representative drugs were used to evaluate the effects of alkyl bonded stationary phases containing type A and type B silica and the effects of an amine modifier on the efficiency of high performance liquid chromatographic elution of basic and acidic drugs. The theoretical plate count and asymmetry factor of the eluted peaks were compared to that of acetophenone as a reference to the maximal efficiency of each system evaluated. Zorbax(R) C8 was used as the stationary phase prepared from type A silica and Zorbax RX(R) was used as the stationary phase prepared from the type B silica. The theoretical plate count and asymmetry factor of acetophenone was observed to be the same on both columns when analyzed in an acidic aqueous/acetonitrile mobile phase. An improvement in the efficiency and peak shape of the amine containing compounds was observed using the Zorbax RX(R) stationary phase as compared to the efficiency and peak shape of these compounds on the Zorbax(R) C8 stationary phase. Interestingly, the acidic compounds salicylic acid and mefenamic acid showed better peak shapes on the Zorbax RX(R) column than on the Zorbax C8. For all drugs studied the theoretical plate count and asymmetry factor was better on both the Zorbax(R) C8 and the Zorbax RX(R) stationary phases when the amine modifier triethylamine was used in the mobile phase. Except for salicylic acid, the theoretical plate count and asymmetry factor for each drug was similar on the Zorbax(R) C8 and the Zorbax RX(R) columns when the amine modifier triethylamine was incorporated into the mobile phase. Analysis of this group of drugs in a solvent programmed systems showed similar peak symmetry as those observed in the isocratic systems of the same stationary and mobile phase conditions.
引用
收藏
页码:3147 / 3175
页数:29
相关论文
共 7 条
[1]   SILANOPHILIC INTERACTIONS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BAYER, E ;
PAULUS, A .
JOURNAL OF CHROMATOGRAPHY, 1987, 400 :1-4
[2]   COMPARISON OF AMINE MODIFIERS USED TO REDUCE PEAK TAILING OF 2-PHENYLETHYLAMINE DRUGS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GILL, R ;
ALEXANDER, SP ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1982, 247 (01) :39-45
[3]   IMPROVED SILICA-BASED COLUMN PACKINGS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOHLER, J ;
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :125-150
[4]   SOLVENT-EXTRACTION OF TRICYCLIC AMINES FROM BLOOD-PLASMA AND LIQUID-CHROMATOGRAPHIC DETERMINATION [J].
LAGERSTROM, PO ;
MARLE, I ;
PERSSON, BA .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (01) :151-160
[5]   INFLUENCE OF MOBILE PHASE ADDITIVES IN LIQUID-CHROMATOGRAPHY OF PHENOXYPROPANOLAMINES [J].
PERSSON, BA ;
JANSSON, SO ;
JOHANSSON, ML ;
LAGERSTROM, PO .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :291-300
[6]   PEAK TAILING AND RETENTION BEHAVIOR OF TRICYCLIC ANTI-DEPRESSANT AMINES AND RELATED HYDROPHOBIC AMMONIUM-COMPOUNDS IN REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY ON ALKYL-BONDED PHASES [J].
SOKOLOWSKI, A ;
WAHLUND, KG .
JOURNAL OF CHROMATOGRAPHY, 1980, 189 (03) :299-316
[7]  
STADALIUS MA, 1988, LC GC, V6, P495