COMPARISON OF ASPIRATION AND SCINTIGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF GASTRIC-EMPTYING RATES OF LIQUIDS IN HUMANS

被引:28
作者
BECKERS, EJ
LEIPER, JB
DAVIDSON, J
机构
[1] UNIV ABERDEEN,DEPT ENVIRONM & OCCUPAT MED,ABERDEEN AB9 1FX,SCOTLAND
[2] ABERDEEN ROYAL INFIRM,DEPT NUCL MED,ABERDEEN AB9 2ZB,SCOTLAND
关键词
D O I
10.1136/gut.33.1.115
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
A comparison was made of two techniques to measure the rate of gastric emptying. A non-invasive scintigraphic technique using a gammacamera and an invasive aspiration technique based on dye dilution were performed simultaneously. Seven healthy male volunteers each consumed two different liquid meals on two separate occasions. Scintigraphic measurements were performed continuously with aspiration every 10 minutes for a total of one hour. Gastric emptying rates were expressed as slope values after semilog linearisation of the emptying curves. Agreement between the two methods was assessed from the individual differences and mean of the two techniques, as well as from the geometric mean, including 95% limits of agreement. The scintigraphic technique gave a 70% slower emptying rate than the dye dilution technique. However, the 95% limits of agreement are large (1.56 to 0.30), reflecting the small sample size and the large coefficient of variation in the techniques used.
引用
收藏
页码:115 / 117
页数:3
相关论文
共 21 条
[1]   APPLIED POTENTIAL TOMOGRAPHY - A NEW NONINVASIVE TECHNIQUE FOR MEASURING GASTRIC-EMPTYING [J].
AVILL, R ;
MANGNALL, YF ;
BIRD, NC ;
BROWN, BH ;
BARBER, DC ;
SEAGAR, AD ;
JOHNSON, AG ;
READ, NW .
GASTROENTEROLOGY, 1987, 92 (04) :1019-1026
[2]   DETERMINATION OF TOTAL GASTRIC VOLUME, GASTRIC-SECRETION AND RESIDUAL MEAL USING THE DOUBLE SAMPLING TECHNIQUE OF GEORGE [J].
BECKERS, EJ ;
REHRER, NJ ;
BROUNS, F ;
TENHOOR, F ;
SARIS, WHM .
GUT, 1988, 29 (12) :1725-1729
[3]  
BECKERS EJ, 1991, MED SCI SPORTS EXERC, V23, P10
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
CHRISTIAN PE, 1980, J NUCL MED, V21, P883
[6]  
CHRISTIAN PE, 1983, J NUCL MED, V154, P537
[7]   GASTRIC-EMPTYING IN NORMAL SUBJECTS - A REPRODUCIBLE TECHNIQUE USING A SINGLE SCINTILLATION CAMERA AND COMPUTER-SYSTEM [J].
COLLINS, PJ ;
HOROWITZ, M ;
COOK, DJ ;
HARDING, PE ;
SHEARMAN, DJC .
GUT, 1983, 24 (12) :1117-1125
[8]  
ELASHOFF JD, 1982, GASTROENTEROLOGY, V83, P1306
[9]   NEW CLINICAL METHOD FOR MEASURING RATE OF GASTRIC EMPTYING - DOUBLE SAMPLING TEST MEAL [J].
GEORGE, JD .
GUT, 1968, 9 (02) :237-&
[10]   CIRCADIAN VARIATION IN GASTRIC-EMPTYING OF MEALS IN HUMANS [J].
GOO, RH ;
MOORE, JG ;
GREENBERG, E ;
ALAZRAKI, NP .
GASTROENTEROLOGY, 1987, 93 (03) :515-518