THE SPECIFICITY OF ANTI-HCV SUPPLEMENTARY ASSAYS
被引:12
作者:
KITCHEN, AD
TUCKER, NV
机构:
[1] Department of Microbiology, Brentwood Blood Transfusion Centre, Brentwood
关键词:
D O I:
10.1111/j.1423-0410.1995.tb01677.x
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
A total of 920 samples from blood donors screened as anti-HCV negative by two third-generation screening assays (Ortho Diagnostics v3.0 and Murex Diagnostics VK48) were tested by two supplementary anti-HCV assays, RIBA III (Ortho Diagnostics) and Western blot (Murex Diagnostics VK68). Six (0.65%) of the samples gave scorable bands by RIBA III and 5 (0.54%) by Western blot. Only single-band reactivity was seen and there was no consensus reactivity between the two assays. Single-band reactivity in supplementary assays, especially in samples from low-risk populations, needs to be interpreted with care before being taken as indication of genuine previous or current HCV infection.