MICROANALYSIS OF BETA-CYCLODEXTRIN AND GLUCOSYL-BETA-CYCLODEXTRIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION

被引:20
作者
KUBOTA, Y [1 ]
FUKUDA, M [1 ]
OHTSUJI, K [1 ]
KOIZUMI, K [1 ]
机构
[1] MUKOGAWA WOMENS UNIV,FAC PHARMACEUT SCI,KOSHIEN KYUBAN CHO,NISHINOMIYA,HYOGO 663,JAPAN
关键词
D O I
10.1016/0003-2697(92)90179-B
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-performance liquid chromatography with pulsed amperometric detection was applied to the determination of β-cyclodextrin (β-CD) and glucosyl (G)-β-CD in human plasma. They were well resolved from each other and from background components of plasma on a polymer-based reversed-phase column with 0.6% acetonitrile aqueous solution containing 1 mM sodium hydroxide as an eluent. The samples in the effluent were detected with a pulsed amperometric detector after postcolumn alkalization. The detection limits of β-CD and G-β-CD in plasma at a signal-to-noise ratio of 3 were 11 and 5 pmol, respectively. © 1992.
引用
收藏
页码:99 / 102
页数:4
相关论文
共 7 条
[1]   DETERMINATION OF CYCLODEXTRINS IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH NEGATIVE COLORIMETRIC DETECTION USING POSTCOLUMN COMPLEXATION WITH PHENOLPHTHALEIN [J].
FRIJLINK, HW ;
VISSER, J ;
DRENTH, BFH .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 415 (02) :325-333
[2]   DETERMINATION OF CYCLODEXTRINS AND BRANCHED CYCLODEXTRINS BY REVERSED-PHASE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION AND A MEMBRANE REACTOR [J].
HAGINAKA, J ;
NISHIMURA, Y ;
WAKAI, J ;
YASUDA, H ;
KOIZUMI, K ;
NOMURA, T .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) :336-340
[3]   RETENTION BEHAVIOR OF CYCLODEXTRINS AND BRANCHED CYCLODEXTRINS ON REVERSED-PHASE COLUMNS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOIZUMI, K ;
KUBOTA, Y ;
OKADA, Y ;
UTAMURA, T ;
HIZUKURI, S ;
ABE, J .
JOURNAL OF CHROMATOGRAPHY, 1988, 437 (01) :47-57
[4]   MICROANALYSES OF BETA-CYCLODEXTRIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOIZUMI, K ;
KUBOTA, Y ;
OKADA, Y ;
UTAMURA, T .
JOURNAL OF CHROMATOGRAPHY, 1985, 341 (01) :31-41
[5]   DETERMINATION OF CYCLIC GLUCANS BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
KOIZUMI, K ;
KUBOTA, Y ;
TANIMOTO, T ;
OKADA, Y .
JOURNAL OF CHROMATOGRAPHY, 1988, 454 :303-310
[6]   ANALYSES OF BRANCHED CYCLODEXTRINS BY HIGH-PERFORMANCE LIQUID AND THIN-LAYER CHROMATOGRAPHY [J].
KOIZUMI, K ;
UTAMURA, T ;
KUROYANAGI, T ;
HIZUKURI, S ;
ABE, JI .
JOURNAL OF CHROMATOGRAPHY, 1986, 360 (02) :397-406
[7]   DETERMINATION OF CARBOHYDRATES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
ROCKLIN, RD ;
POHL, CA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (09) :1577-1590