ANALYTICAL MAGNETAPHERESIS OF FERRITIN-LABELED LYMPHOCYTES

被引:91
作者
ZBOROWSKI, M [1 ]
FUH, CB [1 ]
GREEN, R [1 ]
SUN, LP [1 ]
CHALMERS, JJ [1 ]
机构
[1] OHIO STATE UNIV, DEPT CHEM ENGN, COLUMBUS, OH 43210 USA
关键词
D O I
10.1021/ac00116a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analytical magnetapheresis is a technique for analyzing magnetic particles in suspension. The magnetically susceptible particles form a deposition pattern from the suspending medium under carefully controlled flow and magnetic field conditions. This technique was used to determine the effective magnetic volumetric susceptibility, Delta(chi), of human lymphocytes labeled with an iron-rich protein, ferritin. Dynabeads M450, monodisperse polymeric beads doped with magnetite, of a diameter 4.5 mu m, close to that of human lymphocytes, were used as a reference. The experiment showed an almost complete deposition of ferritin-labeled lymphocytes at an average now velocity of 0.28 mm/s, a representative magnetic field of 1.67 T, and a magnetic field gradient of 2.57 T/mm. The calculated Delta(chi) (2.92 +/- 0.24) x 10(-6)[SI] (ferritin-labeled lymphocytes), and the corresponding number of ferritin molecules per lymphocyte was (1.75 +/- 0.44) x 10(7). In comparison, an almost complete deposition of the Dynabeads was observed at a much higher average now velocity, 15 mm/s, a much lower field, 0.164 T, and a much lower field gradient, 0.025 T/mm. These results corresponded to a much higher Delta(chi) = 0.245[SI] (Dynabeads M450). These results offer important guidelines in evaluating the use of ferritin as a soluble magnetic cell label.
引用
收藏
页码:3702 / 3712
页数:11
相关论文
共 41 条
[1]  
BANGS LB, 1991, J INT FED CLIN CHEM, V2, P188
[2]  
BATTYE FL, 1991, CURR OPIN IMMUNOL, V3, P238
[3]  
BECKER R, 1982, ELECTROMAGNETIC FIEL, pCH103
[4]  
Bird R B., 2007, TRANSPORT PHENOMENA
[5]   ROLE OF IRON AND FERRITIN IN MR IMAGING OF THE BRAIN - A STUDY IN PRIMATES AT DIFFERENT FIELD STRENGTHS [J].
BIZZI, A ;
BROOKS, RA ;
BRUNETTI, A ;
HILL, JM ;
ALGER, JR ;
MILETICH, RS ;
FRANCAVILLA, TL ;
DICHIRO, G .
RADIOLOGY, 1990, 177 (01) :59-65
[6]  
BLAISE A, 1965, CR HEBD ACAD SCI, V261, P2310
[7]  
Coligan JE, 1992, CURRENT PROTOCOLS IM
[8]  
de Petris S, 1972, Eur J Immunol, V2, P523, DOI 10.1002/eji.1830020611
[9]   ISOLATION OF BIOLOGICAL-MATERIALS BY USE OF ERBIUM (III)-INDUCED MAGNETIC-SUSCEPTIBILITIES [J].
EVANS, CH ;
TEW, WP .
SCIENCE, 1981, 213 (4508) :653-654
[10]  
FUNDERUD S, 1987, LYMPHOCYTES PRACTICA, P55